1�3�10    Onboard Connections and Settings

             

Figure 1-6: PXIe-63935 Onboard Configuration

A

SATA Connector

B

Clear CMOS switch

C

System Battery

Table  1-7: Onboard Configuration Legend2

Summary of Contents for PXIe-63935

Page 1: ...PXIe 63935 PXIe Express Embedded Controller User s Manual Manual Rev 1 00 Revision Date Jul 16 2016...

Page 2: ...03 China Tel 86 21 5047 5899 Fax 86 21 5047 5899 Email service jytek com Additional information aids and tips that help users perform tasks Information to prevent minor physical injury component damag...

Page 3: ...ng System Installation 13 2 2 1 Driver Installation 14 2 2 2 Installation Environment 14 2 2 3 Installing the PXIe 63935 15 2 2 4 Replacing the Hard Drive or Solid State Drive 16 2 2 5 Replacing the B...

Page 4: ...III B 3 Advanced Setup 27 B 4 Boot Setup 28 B 5 Security Setup 28 B 6 Save Exit Setup 29 Important Safety Instructions 30...

Page 5: ...t Pin Assignment 10 Table 1 5 PXIe 63935 Ethernet Port Pin Assignments 10 Table 1 6 D Sub 9p COM Port Signal Functions 11 Table 1 7 Onboard Configuration Legend2 12 Table B 1 BIOS Hot Key Functions 27...

Page 6: ...gures Figure 1 1 PXIe 63935 Functional Block Diagram 2 Figure 1 2 Front Panel 5 Figure 1 3 PXIe Trigger SMB Jack 6 Figure 1 4 LED Indicators 9 Figure 1 5 COM Port 11 Figure 1 6 PXIe 63935 Onboard Conf...

Page 7: ...nd one RS 232 422 485 DSUB9 connector for hybrid PXI based testing systems control JYTEK s PXIe 63935 significantly reduces maintenance burdens with easily replaceable battery and upgradable storage a...

Page 8: ...ECC unbuffered memory Front Panel Connectors GPIB USB 2 0 x4 GbE GbE COM port SMB DisplayPort x2 USB 3 0 x2 GPIB GPIB controller GPIB controller I210 Digital Display I F USB 2 0 USB 3 0 SATA LPC COM...

Page 9: ...I O Connectivity Dual Gigabit Ethernet through two RJ 45 connectors with speed link active LED indicators on the front panel with both supporting Wake on LAN USB Four USB 2 0 and two USB 3 0 ports on...

Page 10: ...ock and Vibration values are only guaranteed with use of an JYTEK provided SSD HDD Certification Electromagnetic compatibility EMC EMI CE FCC Class A CE Compliance EN 61326 1 The PXIe 63935 meets the...

Page 11: ...5 1 3 Front Panel I O Indicators Figure 1 2 Front Panel PXIe 63935...

Page 12: ...compatible and edge sensitive The PXIe 63935 provides four trigger routing modes from to the PXIe trigger connector to synchronize PXIe modules including From a selected trigger bus line to PXIe trigg...

Page 13: ...Display Port Pin Assignment 1 3 3 GPIB Connector The GPIB connector on PXIe 63935 is a micro D sub 25P connector controlling external bench top instruments Connection to other instruments requires the...

Page 14: ...round 8 NDAC No Data Accepted 21 Ground Signal Ground 9 IFC Interface Clear 22 Ground Signal Ground 10 SRQ Service Request 23 Ground Signal Ground 11 ATN Attention 24 Ground Signal Ground 12 Chassis G...

Page 15: ...In the event of malfunction clear the CMOS See Clearing CMOS on page 17 and reboot the system If the system fails to respond properly please contact JYTEK for assistance 1 3 6 USB 2 0 Ports The PXIe...

Page 16: ...5 MDI2 Reserved 6 MDI1 RX 7 MDI3 Reserved 8 MDI3 Reserved Table 1 5 PXIe 63935 Ethernet Port Pin Assignments The Ethernet ports each include two LED indicators one Active Link indicator and one Speed...

Page 17: ...RTS N S N S 8 CTS N S N S 9 RI N S N S Table 1 6 D Sub 9p COM Port Signal Functions 1 3 9 USB 3 0 Ports The PXIe 63935 provides two Type A USB 3 0 ports on the front panel supporting SuperSpeed Hi Spe...

Page 18: ...12 1 3 10 Onboard Connections and Settings Figure 1 6 PXIe 63935 Onboard Configuration A SATA Connector B Clear CMOS switch C System Battery Table 1 7 Onboard Configuration Legend2...

Page 19: ...you want to ship or store the product in the future Do not install or apply power to equipment that is damaged or missing components Retain the shipping carton and packing materials for inspection Pl...

Page 20: ...e system and setthe boot device order in the SETUP boot menu accordingly 2 2 1 Driver Installation Download requisite drivers as follows from http www JYTEK com 1 Fully install Windows which contains...

Page 21: ...ling All equipment must be protected from static discharge and physical shock Never remove any of the socketed parts except at a static free workstation Use the anti static bag shipped with the produc...

Page 22: ...e of the PXIe 63935 2 Remove the screws as shown 3 Gently lift and remove the SATA HDD or SSD 4 To install a HDD or SSD or other compatible SATA harddrive reverse the steps and reinstall the PXIe 6393...

Page 23: ...assis Observe all anti static precautions 3 Locate the CMOS clear switch SW1 on the board See Onboard Connections and Settings on page 12 Move the switch from Normal position 2 B to Clear position 2 B...

Page 24: ...C Visual Basic and Delphi for reference Type Description Range Type C C for 32 bit c o m p i l e r Delphi Visual Basic Pascal U8 8 bit ASCII character 0 to 255 unsigned char Byte Byte I16 16 bit signe...

Page 25: ...efore the invocation of any other trigger I O function Supported Controllers PXIe 63935 PXI 63980 Syntax C C I16 TRIG_Init Visual Basic TRIG_Init As Integer Parameter None Return Code ERR_NoError ERR_...

Page 26: ...tus Visual Basic TRIG_SetSoftTrg ByVal status As Byte As Integer Parameters Status Logic level of trigger signal Available value description 0 Logic low 1 Logic high Return Code ERR_NoError ERR_BoardN...

Page 27: ...ing values Available value Description PXI_TRIG_VAL_SMB SMB connector on the front panel PXI_TRIG_VAL_TRIG0 PXIe trigger bus 0 PXI_TRIG_VAL_TRIG1 PXIe trigger bus 1 PXI_TRIG_VAL_TRIG2 PXIe trigger bus...

Page 28: ...setting Supported Controllers PXIe 63935 PXI 63980 Syntax C C I16 TRIG_Trigger_Clear Visual Basic TRIG_Trigger_Clear As Integer Parameters None Return Code ERR_NoError ERR_BoardNoInit ERR_Trigger_Clr...

Page 29: ...2 source U32 dest U32 halfway Visual Basic TRIG_Trigger_Route_Query source As Long dest As Long halfway As Long As Integer Parameters source Returns to the current source of trigger routing with possi...

Page 30: ...VAL_TRIG0 111 PXI_TRIG_VAL_TRIG1 112 PXI_TRIG_VAL_TRIG2 113 PXI_TRIG_VAL_TRIG3 114 PXI_TRIG_VAL_TRIG4 115 PXI_TRIG_VAL_TRIG5 116 PXI_TRIG_VAL_TRIG6 117 PXI_TRIG_VAL_TRIG7 118 Return Code ERR_NoError E...

Page 31: ...n number of the PXIe trigger software driver minor1 Returns the first minor version number of the PXIe trigger software driver minor2 Returns the second minor version number of the PXIe trigger softwa...

Page 32: ...In most cases the Delete key is used to invoke the setup screen There are several cases that use other keys such as F1 F2 and so on The main BIOS setup menu is the first screen that you can navigate...

Page 33: ...etup Utility you will enter the Main setup screen You can always return to the Main setup screen by selecting the Main tab The Main Setup menu provides basic controller information and allows the syst...

Page 34: ...Boot Numlock State Sets keyboard Numlock status Quiet Boot When disabled allows POST messages to be viewed with default Enabled Fast Boot Sets boot with initialization of minimal devices required to...

Page 35: ...ased and reconfigured B 6 Save Exit Setup The following options for saving and exiting can be chosen in this menu Save Changes and Exit Save Changes and Reset Discard Changes and Reset Save Option Sav...

Page 36: ...and or damage to device Keep device away from water or liquid sources Keep device away from high heat or humidity Keep device properly ventilated do not block or cover ventilation openings Always use...

Page 37: ...fore loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up It is recommended that the device be installed only in a server room or computer room...