background image

2

TABLE OF CONTENT

1.  SAFETY AND WARNINGS
2.  USAGE
3.  SET UP AND INSTALLATION
4.  OPERATION
5.  MAINTENANCE AND DEFECTS
6.  TECHNICAL DATA
7.  PARTS
8.  ASSEMBLY DIRECTIONS
9.  DECLARATION OF CONFORMITY

IMPORTANT NOTES !

Prior to installation, use and  

maintenance of the table frame, any  

installer and any user of the table  

must study this assembly and operation 

manual carefully, so as to gain a complete 

understanding of its contents.

WARNING : FAILURE TO COMPLY WITH OR OBSERVE ALL ASSEMBLY, SAFETY AND OPERATION INSTRUCTIONS 
AND WARNINGS REGARDING THE USE OF THIS PRODUCT MAY RESULT IN SERIOUS BODILY INJURY.

1. SAFETY AND WARNINGS

This table complies with the prescribed safety regulations. Inappropriate use may cause damage to persons and table. 
Please read the operation manual prior to using the table. It provides you with important information about safety, use,  
installation and maintenance of the table, and thus protecting you and your children and avoiding damage on the table.
Please guard this operation manual and pass it on to any future owner ! 

2. USAGE

–   The electromotive, height-adjustable tables are designed for workstations in dry work environments only ( 0 - 40° C ; 20 - 90 % relative 

humidity). The table height is infinitely adjustable, so that it can be set to the most ergonomically suitable working level.

–   They have not been designed for other purposes than those included in this manual, e.g. they are not to be used in areas of  

high humidity or dampness, nor for lifting people. Any other use is at one’s own risk !

–  

Do not crawl, lie or move around under the table frame, and do not sit or stand on the table frame. 

–  

CHILDREN should only use the table when supervised by adults.

–  

Liability :  The manufacturer accepts under no circumstances warranty claims or liability claims for damages arising from improper 
use or handling of the table frame other than that described in this operation manual.

3. SET UP AND INSTALLATION

When the table has been assembled ( see assembly instructions in CHAPTER 8 ) the adjustable feet are installed so that the table is level  
and does not shift. Then the table is connected to the 100 -240 VAC outlet and the table is ready for use.
–  Make sure that no cables can get jammed.
–  Place the table in a safe distance from window frames, radiators, furniture etc. so that people do not get stuck.
–  Do not place any objects above 55 cm underneath the table. 
–   When moving the table after it has been assembled, the table top needs to be removed. The table CANNOT be lifted by the table top. 

The desk need to be lowered to minimum height before moving.

Summary of Contents for FORSSA 711-177-1021

Page 1: ...348640 0 FORSSA Assembly instruction Instructions d Assemblage 711 177 1021 711 177 1021 EN Page 2 3 FR Page 4 5 60 min ...

Page 2: ...ve humidity The table height is infinitely adjustable so that it can be set to the most ergonomically suitable working level They have not been designed for other purposes than those included in this manual e g they are not to be used in areas of high humidity or dampness nor for lifting people Any other use is at one s own risk Do not crawl lie or move around under the table frame and do not sit ...

Page 3: ...n 80 Watt Standby consumption 0 15 Watt Max working load on frame 70kg Above specifications may vary depending on local temperature humidity and input voltage 7 PARTS See page 6 8 ASSEMBLY DIRECTIONS See pages 7 9 9 DECLARATION OF CONFORMITY We hereby declare under our sole responsibility that the following products Sit and stand table product type 711 177 1021 is in accordance with Directive 2006...

Page 4: ...a hauteur de la table est réglable en continu de sorte qu elle peut être réglée au niveau de travail le plus ergonomique Ce produit n a pas été conçu à d autres fins que celles incluses dans ce manuel par ex ne doit pas être utilisé dans des zones à forte humidité ni pour élever des personnes Toute autre utilisation est à ses propres risques Ne pas ramper ne pas se déplacer ou s étendre sous le ca...

Page 5: ...tt Consommation en veille 0 15 Watt Charge de travail Max sur cadre 70kg Les spécifications ci dessus peuvent varier en fonction de la température locale de l humidité et de la tension d entrée 7 PIÈCES Voir page 6 8 INSTRUCTIONS D ASSEMBLAGE Voir pages 7 9 9 DÉCLARATION DE CONFORMITÉ Nous déclarons par la présente sous notre seule responsabilité que les produits suivants Table Debout Assis type d...

Page 6: ...e B x4 Driveshaft Arbre de Transmission D x1 Power cable Câble alimentation G x1 Controller Contrôleur J x1 3 5 16H screws K x2 Cable clips Clips de câble L x4 Transformer bracket Support transformateur H x1 Cable tie Attache de câble I x2 Transformer Transformateur F x1 Modesty panel Panneau Modestie M x1 Tabletop Surface N x1 Stiffening rail Renforts O x1 ...

Page 7: ...s Tighten the grub screws with the allen key Do not over tighten grub screws Only very light pressure required D Monter l arbre de transmission télescopique prolonger les deux extrémités sur les ergots de l arbre de transmission Serrer les vis sans tête avec la clé Allen Ne pas trop serrer les vis Seulement une pression très légère requise C x4 ...

Page 8: ... top is fixed to frame See component positions on page 9 4 Le cadre de bureau et le dessus doivent être parallèles avant de fixer la surface NE PAS démarrer le bureau avant que le haut ne soit fixé au cadre Voir les positions des composantes à la page 9 Voir les positions des composantes à la page 9 Pour assurer l opération correcte de montée et de descente du cadre de bureau il doit être équipé d...

Page 9: ...ouge Rouge IMPORTANT Only plug leads red to red and black to black Brancher seulement rouge au rouge et au noir au noir Black Black Noir Noir COMPONENTS POSITION AND WIRING POSITIONS DES COMPOSANTES ET CÂBLAGE x4 G I 5 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Reviews: