background image

[GB 5]

5. Maintenance

Sealing band and vermiculite panels are wearing parts which need to be renewed. How often this is needed depends
on how much you use your stove. In some cases every year, others every second or third year. A principal rule is that
the sealing band needs renewal when it is flattened, and the door no longer fits tightly against the front of the stove. A
new set of sealing band with glue can be purchased from your local dealer.

Vermiculite panels must be renewed when they are worn thin, or when possible cracks are so wide that you can actu-
ally see steel through them. If the panels are not renewed on such occations, they lose their power of insulation and
heat reflection.
Movable and mechanical parts should be greased once a year with a heat-resisting lubricant (closing mechanisms,
hinges etc).

Renewal of the sealing band at the door

1.   Remove the sealing band from the inner frame and clean the band mark (it is not necessary to remove the door 

from the stove).

2.   Add a band of heat-resistant glue on the band mark.
3.   Push new sealing band down into the mark.
4.  Close the door and let the glue harden for about 24 hours, before you open the door again. If you do not let the 

glue harden sufficiently before you open the door, the band may fall out.

Renewal of the sealing band between the Glass and the door of the stove

1.   It is not nescessary to remove the door.
2.   Dismount bolts / Glassholders from the door.
3.   Dismount the bolt and the ratchet that hold the handle. Remove the glass.
4.   Remove the old sealingband from the door.
5.   Add new sealing band to the door.
6.   Insert the glass and tighten the bolts and the glassholders.

Change of the vermiculite panels

1.  The bottom baffle plate is removed.
2.  One of the side plates is removed.
3.  The slanted back plate is removed.
4.  The other side plate is removed.
5.  The lower back plate is removed.
6.  Finally, the top baffle plate is removed.

The baffle plates must be taken out and cleaned regularly as with time, they will accumulate soot and ash. This can 
culminate in prohibiting the smokes clear exit of the fire chamber.

Summary of Contents for SIRIUS

Page 1: ...SIRIUS DK Betjeningsvejledning D Befeuerungsanleitung GB User s manual F Mode d emploi S Användarhandbok N Bruksanvisning NL Bedieningshandleiding IT Istruzioni per l uso ...

Page 2: ... back 2 Installation Jydepejsen stoves are tested by specialist institutions and approved according to applicable legislative requirements Before final approval is granted stoves have to successfully complete a variety of combustion tests The stove tested featured a top outlet The wood used for the tests was birch with a moisture content of 12 20 Jydepejsen s professional distributors will be able...

Page 3: ...our stove No compensation will be granted for Damage during transport Damage to other articles resulting from use of the stove Damage arising from misoperation or incorrect usage such as overheating avoid this by reading the operating instructions carefully The directions in the operating instructions have not been followed The stove is supplied with wearing parts which are to be replaced due to u...

Page 4: ...open at 2 3 4 When the knob is in click 4 the combustion air is fully open 5 When the knob is in click 5 all the way to the right both the combustion and the kindling air are fully open This setting may be used only for a short period of time in the combustion and kindling phase As soon as the wood is ablaze you must turn the knob back to click 4 or further down towards the left depending on your ...

Page 5: ... necessary to remove the door from the stove 2 Add a band of heat resistant glue on the band mark 3 Push new sealing band down into the mark 4 Close the door and let the glue harden for about 24 hours before you open the door again If you do not let the glue harden sufficiently before you open the door the band may fall out Renewal of the sealing band between the Glass and the door of the stove 1 ...

Page 6: ...l bottom 278 x 246 x 30 mm Vermiculite rear panel bevelled 367 x 210 x 25 mm Vermiculite baffle plate upper 380 x 220 x 12 mm Vermiculite baffle plate bottom 390 x 155 x 25 mm We are only able to deliver a complete vermiculiteset and not single parts Glass R 269 x 389 x 85 mm 56900030 Cast iron bottom 56900025 Ash pan Capacity 4 2 l 56900002 Gasket with glue Ø 9 11 mm 44300150 Shaking grate Ø 164 ...

Reviews: