For rear venting or other not listed configurations, consult the local building codes
and follow the NFPA 211 or CAN/CSA-B365 guidelines. If the chimney connector is
fitted with a baffle, it must be manually operated, visibly placed for ease of use, and
must not close completely. Consult your chimney expert if you have any questions.
Make sure that there is easy access to the chimney clean-out door.
Read the instructions on page 8 carefully before connecting: “Chim
-
ney Connector Systems and Clearances from Combustible Walls
for Residential Heating Appliances”.
9
This prevents any amount of condensed or liquid creosote from running down the
outside of the pipe or the stove top. All joints, including the flue collar connection
must be secured with three sheet metal screws to ensure that the sections do not
separate.
For the best performance the chimney connector should be as short and direct as
possible, with no more than two 90° elbows. The maximum horizontal run is 36" and
a recommended total length of single wall stove pipe connector should not exceed
10 feet. Connector pipe over 10 feet must be double wall from the stove collar (not
mixed with single wall except at a masonry thimble per manufacturer's installation
guide). Always slope horizontal runs upward ¼ inch per foot toward the chimney.
Note the connector pipe should not pass through an attic or roof space, closet or
similar concealed space, or a floor or ceiling.
DO NOT CONNECT THIS STOVE TO A CHIMNEY FLUE OR AIR DISTRIBUTION
DUCT OR ANY SYSTEM SERVING ANOTHER APPLIANCE.
For venting vertically into a Class A chimney, single wall pipe (at least 24 gauge)
may be used in the room where the stove is installed. Refer to the manufacturer´s
instructions for the connection to the listed chimney. The chimney / chimney con-
nector must not be smaller than 6" (15 cm) in diameter. For venting directly into a
masonry chimney or through a thimble, the top of the single wall pipe must be at
least 18" (46 cm) below a combustible ceiling and conform to NFPA 211 or CAN/
CSA-B365 guidelines and methods. See diagram below.
Min. 2"
(5 cm)
Min. 2"
(5 cm)
Chimney flue
Connector pipe
18" (46 cm)
below ceiling
Masonry
Insulated chimney
Summary of Contents for Athene
Page 6: ...6 CUBIC 109 166 215 DIAGRAMS FOR CUBIC SERIES CUBIC WALL CUBIC CORNER CUBIC WALL CUBIC CORNER...
Page 10: ...10...
Page 24: ...1 2 3 Trendline soapstone convection 24...
Page 25: ...Trendline with full soapstone cladding Soapstone assembling 6 4 5 2 1 3 6 25...
Page 26: ...Softline with full soapstone or ceramic cladding Soapstone assembling 1 5 cm 1 2 3 7 6 5 4 26...
Page 27: ...Softline with full soapstone or ceramic cladding Ceramic assembling 1 2 3 4 5 6 7 27...