19
Troubleshooting
To contact the factory: Phone (800) 822-7330 or (508) 822-7330; Fax (508) 880-8949; email [email protected]
Web site www.jwfishers.com ; Mail to JW Fishers Mfg Inc, 1953 County St, E. Taunton, MA 02718
Problem 1- Audio pulsates on and off and five dashes (- - - - -) appear in the readout.
This indicates a problem with the signal coming from the Sensor bottle assembly. The system continues to
cycle trying to get a good signal. If its a new unit (never operated in this area before, its possible the tuning
(done at the factory) is dramatically off; see page 15 for tuning. If the unit was working ok, but the audio and
readout indicates this error, then something in the unit has failed. Contact the factory for instructions.
Problem 2 - Audio “wobbles” and the leak LED (on the control panel) is illuminated.
Water has entered the electronics compartment. Remove the control panel (see page 15) and inspect for
water. The tiny leak detector is glued to the inside surface at the bottom of the control panel. Contact the
factory.
Problem 3 - Battery LED blinks on during Polarization time (2 sec). The system automatically monitors battery voltage.
When the battery voltage drops below a preset number the LED illuminates. Maximum current draw is during
Polarization time, so the LED will turn on during this time. When the LED starts to illuminate recharge the
battery overnight. An optional belt mounted spare battery pack is available.
Problem 4 - System stops cycling.
The most likely cause is the battery voltage dropped to low. Recharge the battery overnight. An optional belt
mounted spare battery pack is available.
Please contact the factory if any other problems.