JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS17x, 23x, 34x, 43x
213
8.2.67
Setup_Bits
Description: Bit 0:
Invert motor direction
Bit 1:
Do not start RxP program after power up.
Bit 2-3: Select encoder input type. 0 = Disabled, 1 = Quadrature, 2 = Pulse/direction
Bit 4:
Reserved
Bit 5:
Synchronize encoder position to P_IST after change to active mode.
Follow error = 0
Bit 6:
InPhysPosMode (If set, recalc InPhysPos continuously. If 0, only after stop)
Bit 7-9:
Reserved
Bit 10: EncoderToP_IST (Automatically transfer the absolute single turn encoder posi-
tion to P_IST at power up)
Bit 11: Multiturn (Automatically transfer the multi turn encoder position to actual P_IST
at power up)
Bit 12: KeepExtEncoder (Do not zero the external encoder count on startup)
Bit 13: KeepSSIValue (Do not zero the SSI data register on startup)
Bit 14: UseBeckhoff (use the Beckhoff variant of CAN - required by TwinCAT)
Bit 15: Reserved
Bit 16: External Encoder counting direction (1=inverse)
Bit 17: Disable position limit error. Motor stays in active mode on position limit.
Bit 19: Disable brake (int./ext.) temporarily in order to move the shaft in passive mode.
Bit 20: Disable SSI encoder error. Motor can stay in active mode even if SSI position is
wrong.
Bit 21: "Low bus voltage" gives an Error
Bit 22: "Low bus voltage" sets the motor in Passive mode.
Bit 23: "Low bus voltage" sets V_SOLL to 0 RPM.
Bit 24: Enable closed loop
Bit 25: Enable closed loop current control
Bit 28: Position limits without memory.
These individual bits are used to control various functions in the firmware. Bits marked
in grey are not fully available - consult JVL !.
8.2.68
IOsetup
Description: This register controls the eight IO’s: IO-1 to OI-8. These pins can be used either in
input mode as combined digital and analogue inputs or used in output mode as digital out-
puts. The lowest eight bits in this register can be used to individually invert the active lev-
el of the digital inputs. The highest eight bits are used to select the corresponding
pin as an output.
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
124
SETUP_BITS
32bit
R/W
-
0
Special
Don't start program af-
ter power up.
Invert motor direction.
External Encoder
Support Auto
encoder synchronize
etc. etc. (se below)
Reg
Name
Size
Access
Range
Default
Unit
MacTalk name
125
IOSETUP
32bit
R/W
-
0
Special
Inputs/Outputs
Summary of Contents for MIS17 Series
Page 56: ...56 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 76: ...76 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 266: ...266 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...
Page 318: ...318 JVL Industri Elektronik A S User Manual Integrated Stepper Motors MIS17x 23x 34x 43x ...