Page 1: ...25U VN X235U INSTRUCTIONS Installation LST0926 001A This is a supplementary instruction manual to READ ME FIRST Please read through this manual together with the bundled READ ME FIRST sheet For image and network settings please refer to INSTRUCTIONS Setting ...

Page 2: ...mission is possible in VGA size 640 x 480 at a rate of 30 fps VN V225U Data transmission is possible in Quad VGA size 1280 x 960 at a rate of 15 fps VN X235U Support for dual stream JPEG and MPEG images can be distributed simultaneously Support for multicast This product supports multicast which enables transmission of image data to multiple computers on the network without lowering the frame rate...

Page 3: ...e and Function of Parts 6 Connection Installation Mounting the Camera 10 Embedding the Camera into the Ceiling 10 Mounting with the cables pulled out from the side 12 Connecting the Alarm Input Output Cable 13 Others Troubleshooting 14 Specifications 15 How to read this INSTRUCTIONS Installation 䡵 Symbols used in this manual Note States precautions to be taken during operation Memo States restrict...

Page 4: ...o not block the vents Inadequate heat ventilation may result in malfunction of this product Be sure not to block the vents around the product Copyright Protection 䢇 With the exception of the user being the copyright holder or when permission such as for duplication has been granted by the copyright holder permission is required in principle for the duplication modification or transmission of copyr...

Page 5: ...However this is not a malfunction 䢇 If the power supply voltage is momentarily cut off or reduced due to lightning or turning on of the air conditioner s power the image may be disrupted or noise interference may occur 䢇 The rotation angle of this camera is increased to enable installation at a wider variety of locations When the zoom of the lens is at the wide end and tilted at an angle close to ...

Page 6: ...F Cable outlet Use this outlet to pull out the cable from the side of the camera without making a hole in the ceiling Break the section marked by a dotted line and pull out the cable A page 12 G Alarm cable Audio cable Power cable A READ ME FIRST Note Do not use PoE and an AC24 V power supply at the same time Doing so may cause the camera to break down or malfunction Name and Function of Parts B D...

Page 7: ...using the fall prevention wire fastening hook L L Fall prevention wire fastening hook M Ceiling mounting brackets x3 These brackets are used when embedding the camera to the ceiling A page 10 N Camera unit fastening screw Fastens the camera unit J and the outer casing C How to remove A page 11 O MAC address indication The MAC address is a unique physical address of the product This address cannot ...

Page 8: ... During this interval the RESET button is disabled Focus adjust function press for at least 2 seconds and release in less than 5 seconds The camera enters the focus adjust mode and the status indicator V blinks in green and orange alternately This function can also be used on the viewer Refer to INSTRUCTIONS Setting Note During the focus adjust mode the screen may flicker when the electronic shutt...

Page 9: ...and also the corresponding signal format N Select this when connecting to an NTSC compatible monitor OFF Disables output Select this setting when sending images to the network P Select this when connecting to a PAL compatible monitor Default setting AOFFB Note Images are not sent to the network when this is set to ANB or APB When the switch setting is altered press the RESET button for less than 2...

Page 10: ...ion to remove it To prevent damage to the dome cover a protection sheet is affixed Mounting the Camera Mounting Methods 䢇 Embedding into the ceiling A page 10 䢇 Mounting directly to the ceiling or the wall A READ ME FIRST 䢇 Mounting with the cables pulled out from the side A page 12 Warning Special attention is required when mounting the camera to a wall or ceiling Make sure that the mounting work...

Page 11: ...Memo For details please also refer to the READ ME FIRST sheet provided Note For your safety turn on the power only after all connections are completed 1 Mount the fall prevention wire that connects the camera and the ceiling to the camera unit 2 Connect the alarm cables and audio cables 3 Connect the LAN cable 4 Connect the power cable Note Connection of a power cable is not necessary when PoE is ...

Page 12: ... is complete after the dome cover is mounted and the protective sheet removed A READ ME FIRST Mounting with the cables pulled out from the side When mounting the camera to the ceiling or wall you can pull out the cables from the side without having to make a hole in the ceiling Memo The basic mounting procedures are identical to those described for Direct mounting to the ceiling horizontal mountin...

Page 13: ...s NPN open collector output equivalent Refer to the INSTRUCTIONS Setting on procedures to set the output logic Allowable applied voltage DC 12 V and below Allowable inflow current 50 mA Momentary 100 ms to 5000 ms output Refer to INSTRUCTIONS Setting for procedures to set the time Note Connect the GND cable of the camera to the GND terminal of the alarm device Connecting the Alarm Input Output Cab...

Page 14: ...rivacy mask to AOffB A INSTRUCTIONS Setting Band noise is found at the lower part of the monitor image When using the MONITOR output set the privacy mask to AOffB Images via the network are disrupted Set the MONITOR OUT selection switch to AOFFB and press the RESET button for less than 2 seconds No audio sound is heard from the external microphone Check the connection between the external micropho...

Page 15: ...tage DC 2 7 V typ impedance 2 2 kK typ 䡵 Audio output Line output 200 K max 2 Vp p 䡵 Network output Image compression format JPEG MPEG4 Frame size 1280 960 VN X235U only 640 480 320 240 Horizontal resolution VN V225U 400 TV lines typ VN X235U 700 TV lines typ Network interface RJ 45 100BASE TX 10BASE T FULL HALF Auto negotiation supported Lens VN V225U Focal length f 2 8 mm to 10 5 mm Maximum aper...

Page 16: ...put allowable applied voltage 12 V allowable inflow current 50 mA Internal memory 8 MB Supply voltage AC 24 V or PoE DC 48 V Current consumption AC 24 V 0 35 A PoE 7 W Surrounding temperature 10 I to 50 I operation 0 I to 40 I recommended Ambient humidity 35 RH to 90 RH without condensation Mass Approx 750 g 1 65 lbs Accessories Specifications continued Safety Precautions 1 Read Me First 1 CD ROM ...

Page 17: ...17 Dimension Unit mm inches T Specifications and appearance of this unit are subject to change for further improvements without prior notice ...

Page 18: ... 2009 Victor Company of Japan Limited LST0926 001A VN V225U VN X235U FIXD IP DOME CAMERA FIXD MEGAPIXEL IP DOME CAMERA ...