70
Operations (Step 6 Operations with a Web Browser)
6-4 Settings with a Web Browser (4. Alarm Settings)
Alarm Setting Window:
http://******/alarm-e.html (****** represents the URL of VN-C10.)
This section describes the setting of actions of VN-C10 when an alarm signal has been received.
Item
Effect
Alarm In
Specifies the action when an alarm signal has been received.
Alarm 1 and 2
Specifies the action when an alarm signal has been input to
[Alarm 1] and/or [Alarm 2].
On/Off
Select [On] if the alarm terminals [Alarm 1] and/or [Alarm 2]
are to be used. If not to be used, select [Off].
Alarm Out
If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.
Relay Alarm
Sets the relay alarm function, which is activated when two
alarms are successively received within a certain period of
time.
On/Off
Select whether to enable or disable the relay alarm function.
Relay Alarm Setting
Sets the sequence and interval of alarm input.
Alarm Out
If [On] is selected here, alarm signals are output to the
[ALARM OUTPUT] terminal located on the rear panel.
Alarm Out
On/Off
Select [On] for alarm signals to be output to the [ALARM
OUTPUT] terminal located on the rear panel.
Momentum
Sets the duration for sending alarm output signals.
Value
Sets whether to output high or low signals for alarm output.
Power on Init
If [Yes] is selected, the alarm signal, which was set upon
power connection, is output once.
Caution
•
Perform the output setting appropriately according to the equipment to which signals are
sent.
•
When the alarm setting is complete, check whether the alarm functions are working prop-
erly.
Click [Apply] to update the settings.
VN-C10_E_62-78.pm65e
08/01/03, 9:17 AM
70