No.51921
TM-A101G
27
Item
Test equipment
Test points
Adjustment
locations
Adjustment procedure
NTSC 3.58
CHROMA
Saturation
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S04
(NTSC CHROMA)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK mode from <BLOCK
SELECT> screen.
4. Select the S04 item.
5. Adjust the S04 to become the voltage different
between 75% white and blue to
0V
Ѱ
Ѱ
Ѱ
Ѱ
2Vp-p
as
shown in figure.
NTSC 3.58
PHASE
adjustment
Signal generator
(Full colour bar)
Oscillo-scope
TP-47B
TP-E(
)
[CRT SOCKET
PWB]
S06 (NTSC PHASE)
[SERVICE MENU]
1. Input a NTSC 3.58 full colour bar signal.
2. Connect the oscillo-scope probe to TP-47B and
TP-E(
).
3. Select the SIGNAL BLOCK from SERVICE
MENU.
4. Select the S06 item.
5. Adjust the S06 to become the voltage different
between 75% white and magenta to
0V
Ѱ
Ѱ
Ѱ
Ѱ
2Vp-p
as shown in figure.
0V
2V
BL
B
R
Mg
G
Cy
Y
W
75%
0V
2V
BL
B
R
Mg
G
Cy
Y
W
75%