15
*1 The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.
*2 When selecting the TRIG. (trigger) system, these functions cannot be controlled if no signal is input.
*3 Tally lamp Control and External control (the 7th pin terminal) can be controlled by the MAKE (make contact) system even
when you select the “TRIG.” (trigger) system.
Operation
1. Short-circuit the 7th pin terminal (External control) to the 8th pin terminal (GND) so that the monitor can be controlled by the
external control.
2.
When selecting the “MAKE” (make contact) system,
operate each function by short-circuiting the corresponding pin
terminal to the 8th pin terminal (GND) or opening it.
When selecting the “TRIG.” (trigger) system,
operate each function by Pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second.
NOTES:
• When controlling INP. A or INP. B, only one terminal must be short-circuited. (Other terminals must be opened.)
• When selecting the “TRIG.” (trigger) system, you can operate only one function at a time. Operate the functions one by one.
Display
INP. A
INP. B
CO. OFF
ASPECT
TALLY
TA. SEL
STATUS
Functions to be controlled
Changes the input to INPUT A
Changes the input to INPUT B
Turns on/off COLOR OFF
Changes ASPECT
Controls the tally lamp
Selects the color of the tally lamp
Turns on/off the status display
Opening
Invalid
Invalid
Off
4:3
Off
Green
Off
Short-circuiting
Valid
Valid
On (Monochrome screen)
16:9
On
Red
On
*1
*2
*3
Functions controlled by the MAKE/TRIGGER Terminal
En_11-20_TM-1011G.p65
06.2.14, 22:37
15