background image

RX-5000VBK/RX-5001VGD

1-2

Safety Precautions

1. This  design  of  this  product  contains  special  hardware  and  many  circuits  and  components specially  

for  safety  purposes.    For  continued  protection,  no  changes  should  be  made  to  the  original  design  
unless  authorized  in  writing  by  the  manufacturer.    Replacement  parts  must  be  identical  to  those  
used  in  the  original  circuits.    Services  should  be  performed  by  qualified  personnel  only.

2. Alterations  of  the  design  or  circuitry  of  the  product  should  not  be  made.    Any  design  alterations  of  

the  product  should  not  be  made.    Any  design  alterations  or  additions  will    void  the manufacturer`s  
warranty  and  will  further  relieve  the  manufacture  of  responsibility  for  personal  injury  or  property  
damage  resulting  therefrom.

3. Many  electrical  and  mechanical parts  in  the  products  have  special  safety-related  characteristics.    

These  characteristics  are  often  not  evident  from  visual  inspection  nor  can  the  protection  afforded  
by  them  necessarily  be  obtained  by  using  replacement  components  rated  for  higher  voltage,  
wattage,  etc.    Replacement  parts  which  have  these  special  safety  characteristics  are  identified  in  
the  Parts  List  of  Service  Manual.    Electrical  components  having  such  features  are  identified  by  
shading  on  the  schematics  and  by  (    )  on  the  Parts  List  in  the  Service  Manual.    The  use  of  a  
substitute  replacement  which  does  not  have  the  same  safety  characteristics  as  the  recommended  
replacement  parts  shown  in  the  Parts  List  of  Service  Manual  may  create  shock,  fire,  or  other  
hazards.

4. The  leads  in  the  products  are  routed  and  dressed  with  ties,  clamps,  tubings,  barriers  and  the  

like  to  be  separated  from  live  parts,  high  temperature  parts,  moving  parts  and/or  sharp  edges  
for  the  prevention  of  electric  shock  and  fire  hazard.    When  service  is  required,  the  original  lead  
routing  and  dress  should  be  observed,  and  it  should  be  confirmed  that  they  have  been  returned  
to  normal,  after  re-assembling.

5. Leakage  currnet  check  (Electrical  shock  hazard  testing)

After  re-assembling  the  product,  always  perform  an  isolation  check  on  the  exposed  metal  parts  
of  the  product  (antenna  terminals,  knobs,  metal  cabinet,  screw  heads,  headphone  jack,  control  
shafts,  etc.)  to  be  sure  the  product  is  safe  to  operate  without  danger  of  electrical  shock.
Do  not  use  a  line  isolation  transformer  during  this  check.

Plug  the  AC  line  cord  directly  into  the  AC  outlet.    Using  a  "Leakage  Current  Tester",  measure  
the  leakage   current  from  each  exposed  metal  parts  of  the  cabinet , particularly  any  exposed  
metal  part  having  a return  path  to  the  chassis,  to  a  known  good  earth  ground.  Any  leakage  
current  must  not  exceed  0.5mA  AC  (r.m.s.)

Alternate  check  method
Plug   the  AC  line  cord  directly  into  the  AC  outlet.    Use  an  AC  voltmeter  having,  1,000  ohms  
per  volt or  more  sensitivity  in  the  following manner. Connect  a  1,500    10W  resistor  paralleled by 
a 0.15  F AC-type  capacitor  between an  exposed  
metal  part  and  a  known  good  earth  ground.
Measure the  AC  voltage across the resistor  with the 
AC voltmeter. 
Move the  resistor  connection  to eachexposed metal  
part,  particularly  any  exposed  metal part having  a  
return  path  to the  chassis, and meausre the  AC  
voltage  across  the  resistor. Now, reverse the plug in 
the AC outlet and repeat each measurement. voltage 
measured Any must  not exceed 0.75 V  AC  (r.m.s.). 
This  corresponds  to  0.5 mA  AC  (r.m.s.). 

Warning

1. This equipment has been  designed  and  manufactured  to  meet  international  safety  standards.
2. It  is  the  legal  responsibility  of  the  repairer  to  ensure  that  these  safety  standards  are  maintained.
3. Repairs  must  be  made  in  accordance  with  the  relevant  safety  standards.
4. It  is  essential  that  safety  critical  components  are  replaced  by  approved  parts.
5. If  mains  voltage  selector  is  provided,  check  setting  for  local  voltage.

Good earth ground

Place this 
probe on 
each exposed
metal part.

AC VOLTMETER
(Having 1000 
ohms/volts,
or more sensitivity)

1500     10W

0.15   F  AC TYPE

CAUTION Burrs formed during molding may be left over on some parts of the chassis. Therefore, 

pay attention to such burrs in the case of preforming repair of this system.

Summary of Contents for RX-5000VBK

Page 1: ... RM SR558U REMOTE CONTROL TAPE MD FM AM VCR DVD SOUND CONTROL SLEEP 8 3 2 1 5 SURROUND TEST DELAY 6 5 4 EFFECT CENTER 5 9 8 7 P REAR L 5 TV VCR AUDIO CD 10 10 REAR R MENU ENT 5 TV CH TV VIDEO PHONO CD DISC TV VOL DVD MULTI ONE TOUCH OPERATION VCR CH MUTING VOLUME POWER RX 5000V AUDIO VIDEO CONTROL RECEIVER STANDBY PHONES SPEAKERS 1 2 ADJUST BASS BOOST SETTING MEMORY DVD MULTI CD DVD PHONO VCR TAPE...

Page 2: ...akage currnet check Electrical shock hazard testing After re assembling the product always perform an isolation check on the exposed metal parts of the product antenna terminals knobs metal cabinet screw heads headphone jack control shafts etc to be sure the product is safe to operate without danger of electrical shock Do not use a line isolation transformer during this check Plug the AC line cord...

Page 3: ...ve the front panel assembly Removing the rear panel See Fig 4 1 Remove the top cover 2 Remove 21 screws E on the rear panel 3 Remove 3 screws F on the rear panel 4 Remove the power cord stopper up side 5 Remove the rear panel Removing the tuner board and video board See Fig 5 1 Remove the rear panel 2 Remove 1 screw G on the video board 3 Disconnect the connector CN311 on the video board 4 Disconn...

Page 4: ... 8 screws I on the main board 4 Remove 8 screws J on the power transistor 5 Disconnect the connector CN511 and wire CN831 on the main board 6 Each tie band is cut out 7 Remove 2 screws K on push switch of the front side 8 Remove nut on terminal of the headphone 9 The solder of the wire connected with the transformer is removed 10 Remove the main board Removing the front board See Fig 9 1 Remove th...

Page 5: ...efore adjustment If the heat sink is already warm from previous use the correct adjustment can not be made 3 For L ch connect a DC voltmeter between TP001 s pin1 and pin2 Lch And connect it between pin3 and pin4 Rch 4 30 minutes later after power on adjust VR741 for L ch or VR742 for R ch so that the DC voltmeter value has 1mV 10mV 1 Tuner range FM 87 5MHz 108 0MHz AM MW 530kHz 1710kHz VR742 TP001...

Page 6: ...2 OUT1 AVDD SWIN GNDS SRin SLin GNDC Cin GNDR Rin GNDL Lin BYPASSR BYPASSL LTRE LBASS3 LBASS2 LBASS1 DVDD CLK DATA LATCH DGND AGND SWout SRout SLout Cout Rout Lout AVSS CL1 CL2 CR1 CR2 RTRE RBASS3 RBASS2 RBASS1 OUT PUT PORT volume volume volume volume volume volume MCU I F tone tone 1 Block Diagram M62446FP IC341 6CH Master volume Description of major ICs ...

Page 7: ...nter volume signal input terminal Analog ground terminal R ch volume signal input terminal Analog ground terminal L ch volume signal input terminal Non connect Frequency adjustment terminal tone treble Frequency adjustment terminal tone bass Tone output terminal Frequency adjustment terminal tone bass Frequency adjustment terminal tone treble Frequency adjustment terminal tone bass L R volume inpu...

Page 8: ... BUFFER AM OSC REG AM RF AFC AM AGC O I O I I I AM Local oscillation Signal output This is a terminal of AM Local oscillation circuit Register value between pin 26 and pin28 besides the frequency width of the input signal AM RF signal input This is an output terminal of voltage for FM AFC This is an AGC voltage input terminal for AM O O I O AM detection output FM detection output Mpx input termina...

Page 9: ...Input output port Input output port Data input output Function IF counter signal input IF signal output Not use AM Local OSC signal output FM Local OSC signal input Power suplly VDD 4 5 5 5V When power ON Reset circuit move PLL charge pump output H Local OSC frequency Height than Reference frequency L Low Agreement Height impedance Input for active lowpassfilter of PLL Output for active lowpassfil...

Page 10: ...a signal output to DSP Inhibit detection signal input Clock signal input from RDS Data input from RDS Function switch data signal output Remote control signal input Data start signal for block data to output serial data Stereo indicator output Stereo L Mono H When the set is tuning this terminal becomes L Chip enable output to IC121 Clock signal for IC121 Function switch clock signal output Tuner ...

Page 11: ...ation terminal Oscillation terminal Power supply Center ch relay control signal output Front ch relay control signal output Surround ON OFF control INPUT ATT Indicator control ONE TOUCH OPERATION indicator control STANDBY indicator control Strobe signal output of function switch Data output to IC341 Clock signal output to IC341 Strobe signal output to IC341 I O O O O O O O O O O 2 Pin Function 2 2...

Page 12: ...US CRAM 320w 16b OFP CP DFRAM 64w 16b CRP Gen Lin Log Adj CROM 256w 16b DP Gen DRAM 256w 24b FBUS DBUS FBUS MAC Block SI0 register SO0 register SO1 register DF Block digital Filter MCU I F ADC L ADC R DAC L DAC R DAC C DAC S Self Boot IDEC LC IR PROM 1kw 32b PC Block JMP LDA LDB STABUS FBUS TC9471F IC601 Dolby prologic ...

Page 13: ...l output terminal R channel Ground terminal For DAC R channel Ground terminal For DAC C channel DAC analog signal output terminal C channel DAC analog signal output terminal with attenuator For C channel Reference voltage terminal For DAC C channel Power supply terminal For DAC C channel Reference voltage terminal for attenuator Output buffer Reference voltage terminal for attenuator Input buffer ...

Page 14: ... Operation flag output terminal MCU interface Acknowledge signal output terminal MCU interface Error flag output terminal MCU interface IC bus mode select terminal Self boot control terminal Non connect Power supply terminal Ground terminal Digital ground terminal For ADC L channel Analog ground terminal For ADC L channel ADC analog signal input terminal L channel Reference voltage terminal For AD...

Page 15: ...RX 5000VBK RX 5001VGD 1 15 Internal connections for FL display tube QLF0002 001 DI401 FL DISPLAY TUBE ...

Page 16: ...n Japan 200011 V VICTOR COMPANY OF JAPAN LIMITED AUDIO COMMUNICATION BUSINESS DIVISION PERSONAL MOBILE NETWORK BUSINESS UNIT 10 1 1Chome Ohwatari machi maebashi city 371 8543 Japan No 20883 RX 5000VBK RX 5001VGD ...

Reviews: