(No.YA702<Rev.005>)1-29
5.1.6 DETAILS
Self check is performed for the following items:
5.1.7 METHOD OF DISPLAY WHEN A RASTER IS NOT OUTPUT
In the state where a raster is not output by breakdown of the set, an error is displayed by blink of the POWER LED.
< Explanation of operation >
If error is detected, the power is turned off. Shortly after the power is turned off, POWER LED will be blinked.
When the protection of low bias line short operates, the power cannot be turned on until the power cord takes out and inserts, after
the power is turned off.
Item
OSD
Content
Condition to detect
LOB protect
LOB
LOB protect detected
Start to detect 3sec after LOB is turned on.
Power off if it is being NG for 200ms.
Count is 0-9
EEPROM MEMORY
MEN
Total count of I
2
C error of EEPROM
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
Sound Meister
MEI
Total count of I
2
C error of Eala IC.
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
RF Tuner
TUN
Total count of I
2
C error of RF Tuner
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
HDMI
HDM
Total count of I
2
C error of HDMI
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
Synchronous
SYN
Whether there is Synchronous signal or not? It displays it to the input selecte signal.
The display is OK or NG.
Lamp using time
TIME
Display of panel drive time
When LOB is turned It will be displayed in every
one hour. (Refer to Secton 1)
Clear motion drive
CMD
-
Not used.
AV SW
AV SW
Total count of I
2
C error of AV SW
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
HDMI SW
HDMI SW Total count of I
2
C error of HDMI SW
Start to detect 3sec after LOB is turned on.
Count NG of acquisition I
2
C or NACK.
Count is 0-9
Type of error
POWER LED flash cycle
Low bias line short protection
Power LED turnig on and off at 1 second intervals.