E36
4. Settings (continued)
Contents
Used to reduce noise in the video signal.
LOW/MIDDLE/HIGH :
Noise reduction is performed.
Amount of reduction is increased in the order of LOW
씮
MIDDLE
씮
HIGH.
OFF:
Noise reduction is not performed.
Used to set whether the gamma curve to determine the
reproduction of black is to be the standard value or
customised.
NORMAL:
the gamma curve is set using the standard
value (0.45)
ADJUST:
set when changing the gamma curve
The gamma curve can be adjusted only when gamma is
set to ADJUST.
Increase the number:
Improves the gradation of bright
areas. However, the gradation of
black becomes poorer.
Decrease the number: Improves the gradation of black
areas. However, the gradation of
bright areas becomes poorer.
Selects whether the camera image should be negative
signal.
ON: Conversion to negative signal is made.
OFF: Conversion to negative signal is not made.
Selects whether DSP (Digital Signal Processing) should
be bypassed.
NORMAL: Not bypassed.
BYPASS: Bypassed. In this case the following setting
items are fixed as indicated and cannot be set.
• Detail:
OFF
• Level dep.:
– – –
• Noise sup.:
OFF
• Gamma:
1.00
• Nega:
OFF
• Pixel comp.: OFF
• Color matrix: OFF
Set Value
LOW
MIDDLE
HIGH
[OFF]
[NORMAL]
ADJUST
0.35
:
(0.01 step)
[0.45]
:
(0.05 step)
:
0.90
1.00
ON
[OFF]
[NORMAL]
BYPASS
Item
Noise sup.
Gamma
Level
When
“ADJUST” is
selected.
Nega
DSP bypass
MEMO
Note that details in fine sections of the image may get lost
as the noise reduction amount is increased.
Process settings screen (continued)
Summary of Contents for KY-F75
Page 148: ......