1-26 (No.MA304)
4.5
Jitter value conversion table
Load the test DVD and set the unit to the service mode. A jitter value converted to the hex value is displayed on the LCD.
Refer to the corresponding decimal notation value shown in the following Jitter Conversion Table.
The adjustment is OK if the jitter value measured with a jitter meter is within 12% of the jitter value displayed on the LCD.
If the measured jitter value is outside the 12% tolerance range, adjust it to minimize the difference between the measured value and
the displayed value.
LCD
indication
Jitter value
(%)
LCD
indication
Jitter value
(%)
LCD
indication
Jitter value
(%)
LCD
indication
Jitter value
(%)
EF56
4.7
E972
7.6
E38E
10.5
DDAA
13.4
EF22
4.8
E93E
7.7
E35A
10.6
DD76
13.5
EEEE
4.9
E90A
7.8
E326
10.7
DD42
13.6
EEBA
5.0
E8D6
7.9
E2F2
10.8
DD0E
13.7
EE86
5.1
E8A2
8.0
E2BE
10.9
DCDA
13.8
EE52
5.2
E86E
8.1
E28A
11.0
DCA6
13.9
EE1E
5.3
E83A
8.2
E256
11.1
DC72
14.0
EDEA
5.4
E806
8.3
E222
11.2
DC3E
14.1
EDB6
5.5
E7D2
8.4
E1EE
11.3
DC0A
14.2
ED82
5.6
E79E
8.5
E1BA
11.4
DBD6
14.3
ED4E
5.7
E76A
8.6
E186
11.5
DBA2
14.4
ED1A
5.8
E736
8.7
E152
11.6
DB6E
14.5
ECE6
5.9
E702
8.8
E11E
11.7
DB3A
14.6
ECB2
6.0
E6CE
8.9
E0EA
11.8
DB06
14.7
EC7E
6.1
E69A
9.0
E0B6
11.9
DAD2
14.8
EC4A
6.2
E666
9.1
E082
12.0
DA9E
14.9
EC16
6.3
E632
9.2
E04E
12.1
DA6A
15.0
EBE2
6.4
E5FE
9.3
E01A
12.2
DA36
15.1
EBAE
6.5
E5CA
9.4
DFE6
12.3
DA02
15.2
EB7A
6.6
E596
9.5
DFB2
12.4
D9CE
15.3
EB46
6.7
E562
9.6
DF7E
12.5
D99A
15.4
EB12
6.8
E52E
9.7
DF4A
12.6
D966
15.5
EADE
6.9
E4FA
9.8
DF16
12.7
D932
15.6
EAAA
7.0
E4C6
9.9
DEE2
12.8
D8FE
15.7
EA76
7.1
E492
10.0
DEAE
12.9
D8CA
15.8
EA42
7.2
E45E
10.1
DE7A
13.0
D896
15.9
EA0E
7.3
E42A
10.2
DE46
13.1
D862
16.0
E9DA
7.4
E3F6
10.3
DE12
13.2
E9A6
7.5
E3C2
10.4
DDDE
13.3
Jitter conversion value (DV2.1)
SPEED
1
Calculation
Indicated on the LCD
Jitter (%)
E9A6
7.5