(No.HC027<Rev.001>)1-13
5.1.6 Mount KA-MR100G
(1) Connect Battery cable.
Fig.16
(2) Attach KA-MR100G to KA-UM100G.
Fig.17
(3) Tighten two screws.
Fig.18
(4) Install the rubber sheet.
Fig.19
5.1.7 Install the Battery mount plate
(1) Connect Battery cable and Battery INFO cable.
Fig.20
(2) Tighten four screws.
Fig.21
5.1.8 Set the [INT/EXT] switch to "INT"
Push the bottom side of KA-MR100G to be locked.
Note.
The connector should be placed to the
bottom space.
Set to INT
No communication available through IEEE1394 terminal of KA-UM100G
Note.
After this modification, the IEEE1394 connector of
KA-UM100G becomes no communication available.