adjustment
Signal
generator
Remote
control unit
[4.DEF]
5.TRAPEZ
• Set the FULL mode.
(1) Receive a cross-hatch signal.
(2) Select 5.TRAPEZ.
(3) Set the initial setting value of 5.TRAPEZ.
(4) Adjust to bring the vertical lines at the right and left
edges of the screen parallel.
(5) Press the [MENU] key and memorize the set value.
CORNER
adjustment
Signal
generator
Remote
control unit
[4.DEF]
7.COR-UP
8.COR-LO
9.COR-UP-S
10.COR-LO-S
• Set the FULL mode.
(1) Select 7.COR-UP.
(2) Set the initial setting value of 7.COR.-UP.
(3) Adjust to bring the straight line at the upper corner.
(4) Select 8.COR-LO.
(5) Set the initial setting value of 8.COR-LO.
(6) Adjust to bring the straight line at the low corner.
(7) Press the [MENU] key and memorize the set value.
(8) If the extreame upper & lower corners are a little pin
or barrel chose 9.COR-UP-S or 10. COR-LO-S and
adjust.
(9) Press the [MENU] key and memorize the set value.
ANGLE
adjustment
Signal
generator
Remote
control unit
[4.DEF]
11. ANGLE
• In case where there is a parallelogrammical distortion of
images on the screen.
• Set the FULL mode.
(1) Select 11.ANGLE.
(2) Adjust to bring the vertical lines straight.
(3) Press the [MENU] key and memorize the set value.
Item
Measuring
instrument
Test point
Adjustment part
Description
Parallel
Straight
Straight
Bring the vertical lines straight.