![JVC InteriArt AV-21BX16/L Schematic Diagrams Download Page 21](http://html.mh-extra.com/html/jvc/interiart-av-21bx16-l/interiart-av-21bx16-l_schematic-diagrams_177979021.webp)
1-20 (No.YA465)
V. POSITION
Signal
generator
Remote
control unit
[4. DEF]
1. V-SHIFT
PAL V. POSITION
(1) Receive a circle pattern signal of vertical frequency
50Hz (PAL).
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<1. V-SHIFT>
.
(4) Set the initial setting value of
<1. V-SHIFT>
.
(5) Adjust
<1. V-SHIFT>
to make "
A = B
".
(6) Press the
[OK]
key to memorize the set values.
NTSC V. POSITION
(1) Receive a circle pattern signal of vertical frequency
60Hz (NTSC).
(2) Follow the same step 2 to 6 as in PAL V. POSITION.
V. SIZE
V. ZOOM
Signal
generator
Remote
control unit
[4. DEF]
3. V-SIZE
14. V-ZOOM
PAL V. SIZE
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<3. V-SIZE>
.
(4) Set the intial setting value of
<3.V-SIZE>
to 40.
(5) Adjust
<14. V-ZOOM>
to make the vertical screen
size to
92%
of the picture size.
(6) Press the
[OK]
key to memorize the set values.
NTSC V. SIZE
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL V. SIZE.
H. POSITION
Signal
generator
Remote
control unit
[4. DEF]
4. H-CENT
PAL H. POSITION
(1) Receive a PAL circle pattern signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<4. H-CENT>
.
(4) Set the initial setting value of
<4. H-CENT>
.
(5) Adjust
<4. H-CENT>
to make "
C = D
".
(6) Press the
[OK]
key to memorize the set values.
NTSC H. POSITION
(1) Receive a NTSC circle pattern signal.
(2) Follow the same step 2 to 6 as in PAL H. POSITION.
Item
Measuring
instrument
Test point
Adjustment part
Description
A
B
Picture
size 100%
Screen
size 92%
C
D