(No.YA164)1-21
H. POSITION
Signal
generator
Remote
control unit
[4. DEF]
3.H-CENT.
(1) Receive the PAL circle pattern signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select < 3.H-CENT. >.
(5) Set the initial setting value of < 3.H-CENT. >.
(6) Adjust to became A=B.
(7) Press the [OK] key to memorize the set values.
H. SIZE
Signal
generator
Remote
control unit
[4. DEF]
4.H-SIZE
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select < 4.H-SIZE >.
(5) Set the initial setting value of < 4.H-SIZE >.
(6) Adjust to make sure that the horizontal screen size
of the picture size is
92%
.
(7) Press the [OK] key to memorize the set value.
(8) Input the NTSC VIDEO signal (60Hz) from the EXT
terminal, and make sure that the horizontal screen
size is
92%
.
(9) Press the [OK] key to memorize the set values.
SIDE-PIN
Signal
generator
Remote
control unit
[4. DEF]
6.EW-PIN
(1) Receive the PAL cross hatch signal.
(2) Set the ZOOM mode to REGULAR.
(3) Select 4. DEF from the SERVICE MODE.
(4) Select < 6.EW-PIN >.
(5) Set the initial setting value of < 6.EW-PIN >.
(6) Adjust to make the vertical lines at the right and left
edges of the screen become straight.
(7) Press the [OK] key to memorize the set values.
Item
Measuring
instrument
Test point
Adjustment part
Description
øß÷
øÞ÷
з½¬«®» -·¦» ïððû
ͽ®»»² -·¦»
çîû