1-25
IC DESCRIPTIONS
SYSCON PCB OEC0110A (IC3001)
No.
PORT
PIN NAME
I/O
DESCRIPTION
40
P13/IRQ3
VIDEO_MUTE
OUT
H for at AUTO_CLOCK in POWER OFF. L for except above case.
41
P14/IRQ4
POWER_ON_L
OUT
For control the user power switch ON/OFF.
42
P15/IRQ5
POWER ON-H
OUT
For control the user power switch ON/OFF.
43
P16/IC
REM_IN
IN
Receive the remote control signal.
44
P17/TMOW
DVD RESET
OUT
For control the DVD RESET.
45
P67/RP7/TMB
NC
OUT
Not used.
46
P66/RP6/ADTRG
DVD LED
OUT
The DVD LED light-up/put-off control output.
47
P65/RP5
VCR LED
OUT
The VCR LED light-up/put-off control output.
48
P64/RP4
GRID1
OUT
LEM(LED Module) control terminal.
49
P63/RP3
GRID2
OUT
LEM(LED Module) control terminal.
50
P62/RP2
GRID3
OUT
LEM(LED Module) control terminal.
51
P61/RP1
GRID4
OUT
LEM(LED Module) control terminal.
52
P60/RP0
GRID5
OUT
LEM(LED Module) control terminal.
53
P37/TM0
Y/C CLOCK
OUT
Control terminal for Y/C. (CLOCK).
54
P36/BUZZ
Y/C DATA
OUT
Control terminal for Y/C.(DATA).
55
P35
SEG1
OUT/IN LEM(LED Module) control terminal.
56
VCC
VCC
-
Power of CPU.
57
VSS
VSS
-
Ground.
58
P27
SEG2
OUT
LEM(LED Module) control terminal.
59
P26
SEG3
OUT
LEM(LED Module) control terminal.
60
P25
SEG4
OUT
LEM(LED Module) control terminal.
61
P24/SCL1
IIC CLK
OUT
CLOCK terminal for IIC BUS communication.
62
P23/SDA1
IIC DATA
OUT/IN DATA terminal for IIC BUS communication.
63
P22/SCK1
SEG5
OUT
LEM(LED Module) control terminal.
64
P21/SO1
TX
OUT
Input terminal for DVD communication.(asynchronous)
65
P20/SI1
RX
IN
Output terminal for DVD communication.(asynchronous)
66
P47/RPTRG
SEG6
OUT
LEM(LED Module) control terminal.
67
P46/FTOB
SEG7
OUT
LEM(LED Module) control terminal.
68
P45/FTOA
SEG8
OUT
LEM(LED Module) control terminal.
69
P44/FTID
REEL-S
IN
Input terminal of reel sensor supply.
70
P43/FTIC
REEL-T
IN
Input terminal of reel sensor take up.
71
P42/FTIB
SEG9
OUT
LEM(LED Module) control terminal.
72
P41/FTIA
JUST_CLOCK
IN
not used.
73
P40/PWM14
SEG10
OUT
LEM(LED Module) control terminal.
74
FEW
FEW
IN
FZTAT Write protect.
75
X2
X2
OUT
Subclock pulse(32.768KHz)
76
X1
X1
IN
77
/RESET
/RESET
IN
RESET will be done when the voltage goes to HIGH after the