(No.YD051)1-23
4.4.2 Method of displayed version of firmware
(1) Set the unit to the test mode.
(2) The version number is displayed in the monitor screen.
4.4.3 All-initialization method
Please perform all-initialization according to the following procedures in the following case:
• Just after you exchange the pick-up.
• Just after you exchange the spindle motor.
• Just after you exchange the traverse mechanism base.
NOTE:
Please perform all-initialization when you exchange the parts above and also when you remove the parts above.
(1) Set the unit to the test mode.
(2) Press the REVERSE SKIP/INDEX (
) key of the remote controller for more than 2 seconds.
(3) When initialization is completed, the PLAY (
). mark is indicated in the FDP.
HR-XV48
**
FE/BE VERSION:4624/S2712
NO DISC
Model name
Version of firmware
Others
HR-XV48
**
BE INIT OK
NO DISC