1-4 (No.YA385)
1.2
INSTALLATION
1.2.1 HEAT DISSIPATION
If the heat dissipation vent behind this unit is blocked, cooling
efficiency may deteriorate and temperature inside the unit will
rise. The temperature sensor that protects the unit will be
activated when internal temperature exceeds the predetermined
level and power will be turned off automatically.
Therefore, please make sure pay attention not to block the heat
dissipation vent as well as the ventilation outlet behind the unit
and ensure that there is room for ventilation around it.
Do not put foreign objects near the ventilation holes as this
can result in fire or electrical hazards.
Do not block the ventilation holes as this may cause the
internal temperature to rise and possibly result fire.
1.2.2 INSTALLATION REQUIREMENTS
Ensure that the minimal distance is maintained, as specified
fingure, between the unit with and the surrounding walls, as well
as the floor etc.
Install the unit on stable flooring.
Take precautionary measures to prevent the unit from tipping in
order to protect against accidents and earthquakes.
CAUTION FOR INSTALLATION
• Do not tilt the TV towards the left or right, or toward the back.
• Install the TV in a corner on the floor so as to keep cords out
of the way.
• The TV will generate a slight amount of heat during
operation. Ensure that sufficient space is available around
the TV to allow satisfactory cooling.
1.3
LAMP UNIT HANDLING CAUTION
1.3.1 PRECAUTION FOR LAMP UNIT
The lamp emits high intensity white, ultraviolet and infrared
light. Do not look directly at the light during service.
Also, do not touch the lamp directly as it presents a burn
hazard.
Handle with extra care. This lamp emits high heat and
contains high-pressure during use.
Do not give any impact as this may cause the broken lamp.
1.3.2 HOW TO CONFIRM LAMP OPERATING TIME
• MAXIMUM COUNT TIME=
65535 hours
(1) Press the
[INFORMATION]
key and
[MUTING]
key
simultaneously, then enter the SERVICE MODE.
(2) When the Main Menu is displayed, press
[4]
key to enter
the setting display for designing.
(3) Press
[CH+]
/
[CH-]
key to select the addresses (items).
NOTE:
• Confirmation of the information can be done by selecting
addresses (items) below.
Display position is in the far right side in the 2nd row from the
top, as displayed below.
Intake hole
Exhaust hole
*Diagram differs from actual appearance.
200mm
200mm
150mm
50mm
150mm
*Diagram differs from actual appearance.
LAMP UNIT : TS-CL110EAA
Operating time in decimal number notation (Max. 255)
D070
: Lamp operating time high byte
D071
: Lamp operating time low byte
Operating time in hexadecimal number notation
Operating time in binary number notation
< Calculation example >
D070 (decimal number notation) = 003
D071 (decimal number notation) = 232
(3 x 256) + 232 = 1000 hours
D*** 01
D*** 01
1 01 00000001
1 01 00000001