background image

4

5

Important Safety Instructions

Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that 

produce heat.
Do not defeat the safety purposes of the grounding-type plug.  A ground type plug has two blades and a third grounding  

prong.  The third prong is provided for your safety.  If the provided plug does not fit in to your outlet, consult an electrician  

for replacement of the obsolete outlet.
Protect the power cord from being walked on or pinching particularly at plugs, convenience receptacles, and point where they 

exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart  

is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been damaged in any way,  

such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus 

has been exposed to rain or moisture, does not operate normally, or has been dropped.
Throughout this manual, a number of warning and caution notes may be presented to alert the user to important safety or 

operating information.  Please read and comply with any and all warning and caution notes in this manual.

!

Warnings

 indicate danger that requires proper procedures or practices to prevent injury or 

death to personnel.

!

Cautions

 indicate proper procedures or practices to prevent damage to equipment or  

property.

!

Warning

 – The safe operation of this product requires that a protective earth connection be provid-

ed.  A grounding conductor in the equipment’s mains supply cord provides this protective earth.  To 

reduce the risk of electrical shock to the operator and service personnel, this ground conductor must 

be connected to an earthed ground.  The mains plug shall remain readily operable.

Always adhere to local building, safety and fire prevention codes during the installation and operation of this product.
Use only power cords specified for this product and certified for the country of use.
Connect the unit only to a power source with the specified voltage rating.
Use only fuses of the type and rating specified.
In case of an emergency ensure that power is disconnected.

!

Warning

 – The apparatus shall not be exposed to dripping or splashing and that no objects filled with 

liquids, such as vases, shall be placed on the apparatus.

<2000m

This symbol on the equipment indicates for use at altitudes not exceeding 2000 m.

 

 

Laser Safety Information

This unit is classified as a CLASS 1 LASER PRODUCT according to EN60825-1 (EU) and FDA 21CFR 1040.10 (USA).  Class 1 
laser products are considered safe and do not result in biological hazard if used according to these instructions.

CLASS 1 

LASER PRODUCTS

LASER KLASSE 1 

PRODUKT

!

Warning

 – Use of controls, adjustments or performance of procedures other than those specified 

herein may result in hazardous radiation exposure.

!

Warning

 – Never look directly into the end of the optical fiber while either end of the system  

is operating.

!

Warning

 – Never clean an optical fiber connector on equipment or cable that is carrying light.

!

Warning

 – Always use dust caps on fiber optic connectors when cables are not connected.  This will 

protect the connector from damage and accidental exposure of a human eye to an operating laser.

Summary of Contents for FS-900

Page 1: ...JVC USER MANUAL FS 900Triple Studio Camera Interface System 110 Newton Place Hauppauge NY 11788 800 488 8378 516 671 7278 sales multidyne com www multidyne com FIBER FIRST ...

Page 2: ... base station RX with a single fiber optic cable which can be located near the camera or miles away Contents Important Safety Instructions 4 Laser Safety Information 5 Unpacking the FS 900 Triple Studio Camera Interface System 6 Installation Instructions 6 FS 900 System Description 8 Camera Interface Signal Paths 9 FS 900 JVC Triple Studio Camera Interface System Components 10 Detailed Description...

Page 3: ...quires proper procedures or practices to prevent injury or death to personnel Cautions indicate proper procedures or practices to prevent damage to equipment or property Warning The safe operation of this product requires that a protective earth connection be provid ed A grounding conductor in the equipment s mains supply cord provides this protective earth To reduce the risk of electrical shock t...

Page 4: ...ne cord 1 Mounting Hardware kit Figure 4 Camera and Silverback connections Figure 5 Final mount Neutrik Option Qty Description 1 FS 900BS1N Base Station 3 FS 900CAM1N Camera Head 3 Return video cables 3 Hirose Power cables 1 Line cord 1 Mounting Hardware kit Figure 3 Attaching PCB connector Figure 2 Attaching camera mount plate Step 4 Camera and Silverback connection Connect the MCX connector the ...

Page 5: ...ase Station 2 The FS 900 Camera Head Model numbers of available options FS 900BS1S Base Station with SMPTE connectors FS 900BS1N Base Station with Neutrik connectors FS 900CAM1S Camera Head with SMPTE connectors FS 900CAM1N Camera Head with Neutrik connectors FS 900 System Description 3Gb s HD SDI 1 camera video 3Gb s HD SDI PGM return 1 video 3Gb s HD SDI return 2 video Prompter SDI HDMI common 2...

Page 6: ...standard broadcast camera systems The rigorous qualification and intermateability testing program guarantees consistent and reliable results with all compliant systems Detailed Description Camera Head Unit Connectors FS 900 JVC Triple Studio Camera Interface System Components 1 Battery Connector Anton Bauer Gold mount or V mount 2 Fiber Optic Connector Use either SMPTE or Neutrik cable depending o...

Page 7: ... talkback 3 Intercom Channel 1 2 Talk Active LED Indicator Blinks when the PTT switch has been used to enable talkback on CH 1 or CH2 4 Intercom Channel 1 2 Audio Presence LED Indicator Illuminates when audio is present 5 Program Audio Presence LED Indicator Illuminates when audio is present on either of the two Program Audio channels sent from the Base to the Camera Head units 6 Intercom Channel ...

Page 8: ...quickly toggle the PTT switch up wards and release to disengage CH1 the CH1 LED will turn off then quickly toggle the PTT switch down wards and release to disengage CH2 the CH2 LED will turn off The mic will close and the TALK CH1 and CH2 LED s will all turn off An external switch connected to the DB 15 GPIO connector on the Camera Unit may also be used to control Intercom Talkback operation pleas...

Page 9: ...SDI video RCP data and Fiber Link from Camerasis present 3 SDI Return 1 2 3 Video Presence LED Indicator Illuminates when the Return video channels input has a valid signal on it 4 Intercom Ch1 Ch2 Audio Presence LED Indicator Illuminates when the Intercom Ch1 Audio channel has a valid audio signal on it 5 Program Audio Presence LED Indicator Illuminates when the Program Audio channel has a valid ...

Page 10: ...18 19 Signal Flow Camera Head Signal Flow Base Unit ...

Page 11: ...atus Fiber Status A V Status System Status Back Home Cam Top Menu Camera System Status Camera 1 Camera 2 Camera 3 Back Home Base Fiber Status Menu Base Fiber Status Cam1 Cam2 Cam3 Rx1 xxdBm xxdBm xxdBm Rx2 xxdBm xxdBm xxdBm Rx3 xxdBm xxdBm xxdBm Back Home Base A V Status Menu Base Video Status Cam1 SD HD 3G Ret1 SD HD 3G Cam2 SD HD 3G Ret2 SD HD 3G Cam3 SD HD 3G Ret3 SD HD 3G Ref NTSC PAL HD Back ...

Page 12: ...Home Camera 3 System Status Menu Cam3 System Status CPU Rev ver FPGA Rev ver Vin xx x V Power xx x W Back Home Operation Camera 1 Top Menu Camera 1 Menu Fiber Status A V Status System Status Back Home Camera 1 Fiber Status Menu Cam1 Fiber Status Rx Pwr Temp 1 xxdBm deg C 2 xxdBm deg C 3 xxdBm deg C 4 xxdBm deg C 5 xxdBm deg C Back Home Camera 1 A V Status Menu Cam1 Video Status Cam1 SD HD 3G Ret1 ...

Page 13: ... Type SMPTE EBU LTC Inputs Unbalanced 15Vp p max Outputs Unbalanced 3Vp p max Connector Camera Unit Internal Connector Base Unit BNC Technical Specifications Technical Specifications SDI Video Interface SMPTE ST259 ST292 ST424 Data Rate 270Mbps 1 5Gbps 3Gbps Input output Level 800mVp p Input output Impedance 75 Ohms Connector Camera Unit BNC Connector Base Unit BNC Embedded Audio Supported Yes Vid...

Page 14: ...put 2 4 Wire Intercom Ch1 Output 15 4 Wire Intercom Ch2 Output 3 GND 16 GND 4 4 Wire Intercom Ch1 Input 17 4 Wire Intercom Ch2 Input 5 4 Wire Intercom Ch1 Input 18 4 Wire Intercom Ch2 Input 6 PGM Audio Ch1 Input 19 PGM Audio Ch2 Input 7 PGM Audio Ch1 Input 20 PGM Audio Ch2 Input 8 GND 21 GND 9 GND 22 N C 10 Intercom MIC Kill GPI Input 23 N C 11 N C 24 N C 12 GND 25 GND 13 GND Base Unit GPIO Connec...

Page 15: ...elect GPI Input 13 N C 6 GND 14 N C 7 GND 15 12VDC Output 8 GND Camera Unit Audio Connector Pinout Number Description Number Description 1 GND 6 PGM Audio Ch1 Output 2 PGM Audio Ch1 Output 7 GND 3 PGM Audio Ch2 Output 8 PGM Audio Ch2 Output 4 GND 9 N C 5 N C Camera Unit Intercom Headset Audio Connector Pinout Number Description 1 GND 2 MIC Input 3 GND 4 Audio L Output 5 Audio R Output Camera Unit ...

Page 16: ...110 Newton Place Hauppauge NY 11788 800 488 8378 516 671 7278 sales multidyne com www multidyne com 2016 MultiDyne Inc MDDOC00170 RevA November 2016 ...