18 (No.PA056<Rev.002>)
4.4.4 Transferring CMS Data from DD PWB
Note:
• Perform the operation with the power ON.
• Input the signal from external equipment.
PROCEDURE
(1) Run the VP Writer application program.
(2) Select the COM Port.
(3) Click "Write".
(4) CMS data is transferred from the DD PWB.
< If OK >
< If NG >
4.4.5 Adjustment data backup of DD PWB
Note:
• Perform the operation with the power ON.
• Input the signal from external equipment.
BACKUP PROCEDURE
(1) Run ServiceCommander Software.
(2) Select Com Port, then connect the PC to the projector
and click "Connect".
(3) Select the EEPROM menu.
(4) Click [DD Adjust Mode] of DD set ON.
(5) Click A0 of [Read From ROM] and save the anf0 file to
the PC.
(6) In the similar procedure for save the A2,A4,A6 memory.
(7) Click [DD Adjust Mode] of DD set OFF.
PROCEDURE
(1) Run ServiceCommander Software.
(2) Select Com Port, then connect the PC to the projector
and click "Connect".
(3) Select the EEPROM menu.
(4) Click [DD Adjust Mode] of DD set ON.
(5) Click A0 of [Write to ROM] of DD and load of backup the
anf0 file to the PC.
(6) In the similar procedure for the A2,A4,A6 memory.
(7) Click [DD Adjust Mode] of DD set OFF.
4.4.6 Pixel shift adjustment
PROCEDURE
(1) Input color cross-hatch signal.
(2) From the Service menu, set < Adjust > to < Pixel Shift >.
(3) Adjust [H Pixel Adj.R], [H Pixel Adj.B] to make H direction
(Pixel Shift) to become the best point.
(4) Adjust [V Pixel Adj.R], [V Pixel Adj.G] to make V direction
(Pixel Shift) to bectom best point.
4.4.7 Lenz position reset
PROCEDURE
(1) Set lens shift position to mechanical center.
(2) Execute to Lens Position Reset.
Instruments
VPWriter
REPLACING
COMPONENTS
PROCESSOR PWB
OP UNIT
Test point
Adjustment menu
Preparation
Instruments
ServiceCommander
Software
REPLACING
COMPONENTS
DD PWB
Test point
Adjustment menu
Preparation
Instruments
REPLACING
COMPONENTS
OP UNIT
Test point
Adjustment menu Service menu
“Adjust”
“Pixel shift”
Preparation
Instruments
REPLACING
COMPONENTS
OP UNIT
Test point
Adjustment menu Service menu
“Option”
“Lens Posi-
tion Reset ”
Preparation