![JVC D-ILA DLA-HD1-BC Service Manual Download Page 27](http://html.mh-extra.com/html/jvc/d-ila-dla-hd1-bc/d-ila-dla-hd1-bc_service-manual_179708027.webp)
(No.PA023)1-27
5.3
ERROR LOG (SELF-DIAGONOSIS RECORD AND INDICATION)
5.3.1 Outline
By using the special setting and adjustment software, data related to abnormal operation (history) stored in the projector can be load.
On the basis of contents "LED (INDICATOR) WARNING INDICATONS" set and lamp use time, internal and external temperature, and
other data prior to the previous usage time can be viewed as a table.
z
HOW TO LOAD THE DATA FROM UNIT
(1) Install the software in a personal computer and connect
by RS-232C IN terminal (use cross cable).
(2) Set the projector to stand-by mode.
(3) Start the setting and adjustment software.
(4) Click the [Receive] button and save the TEXT file. Data
become the latest data so as to go below.
(5) The first number is error code.
(6) Click the [Reset] button and delete all data stored in pro-
jector.
z
ERROR LOG SCREEN ITEMS
Example
㧦
F2, 7, 142, 22, 31, 31, 00000000
ERROR CODE
FACTORY USE
No.
Item
Detected condition
1
Error code 01:No projection caused by the lamp failure.
02:Lamp usage time has exceeded 2000 hours.
03:Error of IIC data
06:Lamp extinction during the projection
07:Ventilation fan in the unit is stopped. [Fan Lock]
08:Internal temperature becomes extraordinarily higher.
09:Exhaust temperature at the vent is extraordinarily high or forced high due to high ambient temperature
11:SUB CPU malfunctions.
15:The lamp cover is removed
16:Error communication in DD CPU
17:DD CPU is reset
18:DD CPU malfunctions.
20:Lamp did OFF by sleep time function.
F0:Just after POWER ON
F1:Once a hour after POWER ON
F2:POWER OFF(Included Emergency mode)