No. 51776
AV28WT5EPS AV24WT5EPS
AV28WT5EIS AV24WT5EIS
AV28WT5EKS AV24WT5EKS
23
ADJUSTMENTS
CHECK ITEM
Item
Measuring
instrument
Test point
Adjustment part
Description
Check of B1
Power Supply
Signal
Generator
DC voltmeter
Remote
Control unit
TP-91(B1)
TP-E(
#
#
#
#
)
[X connector
on POWER
DEF PWB]
1. Receive a any broadcast.
2. Push the “ZOOM” key and select the FULL mode.
3. Select 2. V/C from the SERVICE MENU.
4. Select 1. CUT OFF with Function UP / DOWN key.
5. Show one horizontal line with the 1 key.
6. Turn the SCREEN VR, the whole black screen display.
7. Connect a DC voltmeter to TP-91(B1) and TP-E(
#
).
8. Make sure that the voltage is DC144.5
±
2.0V.
9. Readjust the SCREEN VR to appear the horizontal line faintly,
and cancel the horizontal line to press the 2 key.
Check of High
Voltage
Signal
Generator
DC volunteer
Remote
Control unit
CRT anode
Chassis GND
1. Receive a any broadcast.
2. Push the “ZOOM” key and select the FULL mode.
3. Select 2. V/C from the SERVICE MENU.
4. Select 1. CUT OFF with Function UP / DOWN key.
5. Show one horizontal line with the 1 key.
6. Turn the SCREEN VR, the whole black screen display.
7. Connect a DC voltmeter to CRT ANODE and chassis GND.
8. Make sure that the voltage is DC 30.0kV .
9. Readjust the SCREEN VR to appear the horizontal line faintly,
and connect the horizontal line to press 2 key.
ADJUSTMENT OF FOCUS
Item
Measuring
instrument
Test point
Adjustment part
Description
Adjustment of
FOCUS
Signal
generator
FOCUS VR
[In FBT]
1. Receive a cross-hatch signal. Select FULL mode.
2. While watching the screen, adjust the FOCUS VR to make the
vertical and horizontal lines as fine and sharp as possible.
3. Make sure that when the screen is darkened, the lines remain
in good focus.
+1kV
-1.5kV
SCREEN VR
FOCUS VR