1-18 (No.52137)
HORIZONTAL
POSITION
adjustment
Signal
generator
Remote
control unit
038
118 (16:9 mode)
(1) Receive a PAL circle pattern signal.
(2) Enter the SERVICE MENU.
(3) Select ADJUST MENU.
(4) Select 038.
(5) Adjust 038 to make C=D.
(6) Check and readjust 038 item if the adjustment
becomes improper after some other geometric
adjustments are done.
(7) Select 118 (16:9 mode).
(8) Adjust 118 in the same procedure.
HORIZONTAL
SIZE
adjustment
Signal
generator
Remote
control unit
039
119 (16:9 mode)
(1) Receive a PAL cross-hatch signal.
(2) Enter the SERVICE MENU.
(3) Select ADJUST MENU.
(4) Select 039.
(5) Adjust 039 until vertical lines on both the left and
right part of the cross-hatch will be visible nor screen
will be so wide.
(6) Check and readjust 039 item if the adjustment
becomes improper after some other geometric
adjustments are done.
(7) Select 119 (16:9 mode).
(8) Adjust 119 in the same procedure.
ANGLE
adjustment
Signal
generator
Remote
control unit
016
(1) Receive a PAL cross-hatch signal.
(2) Enter the SERVICE MENU.
(3) Select ADJUST MENU.
(4) Select 016.
(5) Adjust 016 till the vertical lines of the cross-hatch
pattern become straight.
(6) Check and readjust 016 item if the adjustment
becomes improper after some other geometric
adjustments are done.
Item
Measuring
instrument
Test point
Adjustment part
Description
C
D
Screen size
Very
close
Very
close
Picture size 100%