Timer Programming

A

Press 

MENU

. Press 

w

 

e

 to select the icon 

“REC”, then press 

OK

. The programme list 

appears.

B

Press 

OK

C

Press the appropriate 

number keys

 to 

set the channel, date, start time and stop 
time. Input “0” before any single number 
entries.

To time-record daily (Monday–Friday) or 
weekly serials, press 

w

 

e

 to select the 

“DATE” setting, then press 

OK

. Press 

w

 

e

, then press 

OK

.

To set VPS/PDC, press 

w

 

e

 to select the 

space between the stop time and the 
tape speed, then press 

rt

. If you set 

“VPS/PDC” to “ON”, “ ” appears. 

“VPS/PDC Recording” below.

HR-V505/V506/V507E only

To set the tape speed (SP/LP/IP), press 

w

 

e

 to select the tape speed, then press 

rt

“Intelligent LP Recording (HR-V505/V506/V507E only)” on 

the right column.

D

Press 

MENU

. Press 

MENU

 again to return to normal screen.

E

Press 

1

. The recorder enters timer standby mode. The timer 

indicator and standby/record indicator light on the display panel.

If a cassette has not loaded when the recorder enters the timer 
standby mode, the timer indicator blinks on the display panel.

To timer-record a satellite broadcast using Timer Programming:

A

Perform steps

1

5

. In step

3

, set the channel position to 

“AV2”.

B

Set the satellite receiver to the appropriate channel before the 

selected programme begins.

C

Leave the satellite receiver’s power on.

VPS/PDC Recording

Now available from some TV stations, PDC (Programme Delivery 
Control) and VPS (Video Programme System) are service designed 
to assure safe, accurate timer recording. With this system, your 
recorder will start and stop recording when the preset TV 
programmes actually start and end — even if the broadcast time of 
a preset TV programme is changed.

NOTES:

PDC recording is not possible in Central and Eastern Europe.

It is not possible to set the tape speed to “IP” with “VPS/PDC” 

set to “ON”.

When you use Timer Programming, set the start time (VPS or 

PDC time) exactly as advertised in the TV listing.

Intelligent LP Recording (HR-V505/V506/V507E only)

When you set the tape speed to “IP”, the recorder automatically 
switches to LP mode to allow complete recording if there is not 
enough tape to record the entire programme while timer-
recording in SP mode.

For example, 

recording a programme of 210 minutes in length 

onto a 180-minute tape.

NOTES:

If you have programmed the recorder to timer-record 2 or more 

programmes, do not use this function, but change the tape 

speed manually during timer programming.

There may be some noise and sound disturbance where the 

tape speed switches from SP to LP mode on the tape.

This function is not available during ITR (Instant Timer 

Recording), and will not work properly with any tapes longer 

than E-180 or with some tapes of shorter lengths.

It is not possible to set the tape speed to “IP” with “VPS/PDC” 

set to “ON”.

Checking, canceling or changing programme 
settings

A

Disengage timer recording standby mode

Press 

1

.

B

Access Main Menu screen

Press 

MENU

. Press 

w

 

e

 to select the icon 

“REC”, then press 

OK

. The programme list 

appears.

C

Cancel or change programme setting

To cancel a programme,

 press 

rt

 to 

select the programme you want to delete, 
then press 

w

.

To change a programme,

 press 

rt

 to 

select the programme, then press 

OK

Press 

w

 

e

 to select the item you want to 

change, then press the 

number keys

 or 

rt

 to change the settings.

After confirming all information is correct, press 

MENU

.

D

Return to normal screen

Press 

MENU

.

E

Re-engage timer recording standby mode

Press 

1

. The recorder enters timer standby mode. The timer 

indicator and standby/record indicator light on the display panel.

REC

ARD

- -

Approximately 150 minutes

Approximately 60 minutes

SP mode

LP mode

Total 210 minutes

REC

HR-V505_205E-001EN.fm  Page 13  Friday, January 31, 2003  6:13 PM

Summary of Contents for 0203-AH-CR-LG

Page 1: ...IRST CAUTION 䡲 When you are not using the recorder for a long period of time it is recommended that you disconnect the power cord from the mains outlet 䡲 Dangerous voltage inside Refer internal servicing to qualified service personnel To prevent electric shock or fire hazard remove the power cord from the mains outlet prior to connecting or disconnecting any signal lead or aerial WARNING There are...

Page 2: ...e control Before use insert the Lithium battery CR 2032 in the correct directions as indicated back of the remote control The remote control can operate most of your recorder s functions as well as basic functions of JVC TV sets Point the remote control toward the receiving window on the recorder The maximum operating distance of the remote control is about 7 5 m To operate your JVC TV press the c...

Page 3: ...9 Playe Stop Eject0 Record7 Rewind 3 Fast Forward5 Mains power cord See ATTENTION below About 1 Button When you press 1 on the recorder and remote control while the recorder is turned on each button works differently On the recorder When you press 1 the recorder is turned off completely On the remote control When you press 1 the recorder enters the standby mode The clock display will be auto dimme...

Page 4: ...ring recording RECP appears in the record pause mode SAFE appears when the recorder enters in child lock mode or any buttons on the recorder are pressed during child lock mode 墌 15 Icon Description A REC Select this icon to timer record the programme 墌 13 B PR SET Select this icon to perform Manual Channel Set 墌 8 9 C ACMS Select this icon to perform Auto Channel Set 墌 7 Auto Channel Set automatic...

Page 5: ...s on the screen NOTE When you use the recorder as the source player for editing a tape be sure to set this function to OFF Otherwise the recorder status information will be recorded on the edited tape I 16 9 4 3 AUTO 16 9 4 3 You can select the aspect ratio of your TV AUTO Normally select this You can play back the 16 9 and 4 3 screen programme as they are 16 9 You can play back the programme with...

Page 6: ...om RF connection to AV connection or vice versa If you have connected the recorder to your TV via the AV connection set the video channel to off If you have connected the recorder to your TV via the RF connection set the correct video channel A Set the channel on TV Select the vacant position 36 on your TV B Access Video Channel Set mode Press 1 on the remote control to enter the standby mode Pres...

Page 7: ...y stations in channel positions in order to record TV programmes Auto Channel Set automatically assigns all receivable stations in your area Auto Channel Set A Access Main Menu screen then Auto Channel Set screen Press MENU Press w e to select the icon ACMS then press OK The Country Set screen appears B Select your country Press w e to select your country C Perform Auto Channel Set Press OK When A...

Page 8: ...select the channel you want to delete D Delete channel Press w The channel directly beneath the cancelled one moves up one line Repeat steps 3 4 as necessary E Return to normal screen Press MENU Changing station channel positions A Access Main Menu screen then Manual Channel Set screen Press MENU Press w e to select the icon PR SET then press OK The Manual Channel Set screen of the channel positio...

Page 9: ...u want to tune then press OK D Perform tuning Press w e to select MFT setting then press rt until the picture is its clearest Repeat steps 3 4 as necessary E Return to normal screen Press MENU twice TV station and ID list The STATION abbreviation is what is shown on screen in lieu of the station name The STATION abbreviation is listed in the Confirmation screen and is displayed on the screen when ...

Page 10: ... control OR Press 0 on the recorder Pause playback and view still picture Press 9 The recorder enters Pause mode after moving 2 or 3 frames If there is vertical jitter use the PR to correct the picture Press 4 to resume normal playback Still picture playback stops automatically after about 5 minutes to protect the heads Pause and Frame by Frame playback Press 9 to pause then press 9 repeatedly Pre...

Page 11: ...ears on the screen while the one selected with the PR is recorded on the tape If a decoder is connected to the recorder you can select a scrambled channel as well with the TV channel controls Specifying recording length Instant Timer Recording ITR During recording press 7 ITR repeatedly until the desired recording length appears on the screen Each time you press the button recording length increas...

Page 12: ...n input a valid SHOWVIEW number C Check the settings If is displayed on the channel position press w e to select then press the number keys or rt to select the channel position you want to record manually This channel position is registered to the recorder To change the channel position press w e to select the PR setting then press the number keys or rt to select the channel position you want to r...

Page 13: ...rn Europe It is not possible to set the tape speed to IP with VPS PDC set to ON When you use Timer Programming set the start time VPS or PDC time exactly as advertised in the TV listing Intelligent LP Recording HR V505 V506 V507E only When you set the tape speed to IP the recorder automatically switches to LP mode to allow complete recording if there is not enough tape to record the entire program...

Page 14: ...onnector via a cable adapter B Load cassettes Insert the playback cassette into the source player and the cassette to be recorded on into the recording deck C Select input mode on recording deck Select the correct external input on the recording deck On this recorder press AV and or PR Select AV1 for the EURO AV1 AUDIO VIDEO connector or AV2 for the EURO AV2 DECODER connector D Select edit mode Se...

Page 15: ...1 pin SCART connector using a 21 pin SCART cable Connecting Using a stereo system HR V505 V506 V507E only You can listen to the soundtrack through your stereo system Connect the AUDIO OUT L and R connectors on the recorder to the AUX IN or TAPE MONITOR connectors on your stereo system s receiver or amplifier When listening to sound through the connected stereo system turn the TV s volume down comp...

Page 16: ...nal system PAL type colour signal and CCIR monochrome signal 625 lines 50 fields Recording Format PAL MESECAM RF reception PAL B G SECAM B G RF OUT PAL G RF modulator UHF channels 22 68 Adjustable Input level VIDEO IN SCART type 1 0 Vp p 75 ohm unbalanced Output level VIDEO OUT SCART type 1 0 Vp p 75 ohm unbalanced Signal to noise ratio More than 43 dBm AUDIO Input level AUDIO IN SCART type 6 0 dB...

Reviews: