11
ENGLISH
Computer signals (preset)
DVI-D (HDCP) terminals
No.
Signal name
Resolution
Frequency
Scan system
Horizontal
Vertical
Horizontal
(kHz)
Vertical (Hz)
1
VGA60
640
480 31.5
59.9
Non-interlace
2
WVGA60
852
480
31.5
59.9
Non-interlace
3
SVGA60
800
600
37.9
60.3
Non-interlace
4
XGA60
1024
768
48.4
60.0
Non-interlace
5
WXGA (1280)
1280
768
47.8
60.0
Non-interlace
6
WXGA+60
1440
900
55.9
60.0
Non-interlace
7
SXGA60
1280
1024
64.0
60.0
Non-interlace
8
WSXGA+60
1680
1050
65.2
60.0
Non-interlace
9
UXGA60*
5
1600
1200
75.0
60.0
Non-interlace
10
WUXGA60*
5
1920
1200
74.0
60.0
Non-interlace
11
720/60p
1280
720
45.0
60.0
Non-interlace
12
1080/60p*
5
1920
1080
67.5
60.0
Non-interlace
13
720/50p
1280
720
37.5
50.0
Non-interlace
14
1080/50p*
5
1920
1080
56.25
50.0
Non-interlace
*
5
For DT-V20L3G: When No. 9, 10, 12 or 14 signals come in, thin lines will become obscured because their signal
resolution is higher than the screen resolution.
• Non-preset signals may not be displayed normally even if their frequency is within the acceptable range (
☞
“Horizontal/vertical frequency (computer signal)” on page 26).
• When a preset signal comes in, the signal format is shown on the status display. For other signals, the
resolution is shown.
Specification of the DVI-D (HDCP) terminal
Connect it to the DVI-D output terminal on a personal computer.
Pin
No.
Input signal
Pin
No.
Input signal
Pin
No.
Input signal
1
T.M.D.S Data 2–
9
T.M.D.S Data 1–
17
T.M.D.S Data 0–
2
T.M.D.S Data 2+
10
T.M.D.S Data 1+
18
T.M.D.S Data 0+
3
T.M.D.S Data 2 shield
11
T.M.D.S Data 1 shield
19
T.M.D.S Data 0 shield
4
NC
12
NC
20
NC
5
NC
13
NC
21
NC
6
DDC Clock
14
+5 V Power
22
T.M.D.S Clock shield
7
DDC Data
15
GND
23
T.M.D.S Clock+
8
NC
16
Hot Plug Detect
24
T.M.D.S Clock–
Status indication of DUAL LINK/3G SDI signal information
When DUAL LINK and 3G SDI signals come in, the status of DUAL LINK is displayed. When “SDI DUAL
LINK” (
☞
page 12) in MAIN MENU is set to “OFF” and a 3G SDI signal comes in, the 3G SDI signal
information is displayed.
Status indication of DUAL LINK
When “SDI DUAL LINK” (
☞
page 12) in MAIN MENU is set to “ON” and an SDI signal is selected, “DUAL
LINK” is displayed.
Status indication of 3G SDI signal information
Following signal information can be displayed when a 3G SDI signal comes in.
3G A-1:
Level A mapping structure 1
3G A-2:
Level A mapping structure 2
3G A-3:
Level A mapping structure 3
3G A-4:
Level A mapping structure 4
3G B-DS1:
Level B data stream 1
3G B-DS2:
Level B data stream 2
3G B-DUAL:
Level B DUAL LINK
NOTE
DT-V24G1_20L3G_EN.indd 11
DT-V24G1_20L3G_EN.indd 11
10.1.15 3:22:19 PM
10.1.15 3:22:19 PM