background image

JVA SMS Gateway User Manual 

Querying the GSM signal 

The  GSM  status  of  the  unit  can  be  requested  by  issuing  a 

gsm

  command.    The  unit  will  reply  with 

signal strength from 1 to 30, and the firmware version. 

Report List 

The unit can store up to 10 phone numbers which it will SMS if a device goes into alarm or an input 
changes.    This  list  is  configured  and  maintained  using  the 

add 

and 

remove

  commands.    You  can 

retrieve the current list of numbers using the 

numbers

 command. 

Issuing an 

add

 command with no further parameters will add the sending number to the report list.  

Issuing an 

add

 command, followed by a valid number, will add the supplied number to the report list.  

Numbers can be in either the national format, eg 0412 345 6789, or international dialling format, eg 
+61  412  345  6789.    International  format  is  recommended,  as  this  reduces  the  chance  of  adding 
duplicate numbers to the list.  If this were to happen, that number would receive two messages each 
time an SMS is broadcast.  After successfully adding a number the unit will reply with a confirmation 
message. 

Numbers can be removed by issuing the 

remove 

command.  If no parameter is supplied, the sending 

number is removed.  If the parameter is supplied it can be either the number you wish to remove, or 
the position of the number in the report list.  If entering a number, it must be in the same format as it 
is stored in the list.  After successfully removing a number the unit will issue a confirmation message. 

Controlling Energisers and Outputs 

The unit can turn all energisers on (arm) or off (disarm) by issuing the 

on

 or 

off

 commands.  When 

arming, the unit will arm in high power only, and arm both channels of any dual channel energisers.  
When  the  unit  has  confirmed  the  new  arm  state  it  will  reply  to  the  sender  with  a  confirmation 
message, or a message indicating it was  unable to control all devices (in the case of a device being 
offline). 

The unit has two relays than can be turned on or off.  Issue an 

output1 

or 

output2 

command with 

the parameter 

on 

or 

off

.  Note there is no space between “output” and the number “1” or “2”.  The 

unit will reply with a confirmation message. 

Alerting users 

The unit monitors the connected energisers and will send a SMS to everyone on the report list if the 
following things occur: 

 

A fence alarm occurs, usually due to a short on the fence 

 

An energiser stops communicating 

 

An input changes 

If multiple energisers report changes at the same time, the unit will send one SMS for each change. 

Summary of Contents for PTE0319

Page 1: ...www jva fence com au JVA SMS Gateway User Manual PTE0319...

Page 2: ...y country Simply insert a valid topped up SIM card from your preferred carrier and you are ready to remotely control and monitor your energisers from anywhere in the world Features Works with entire J...

Page 3: ...3 Antenna 4 Power and Keypad Bus 4 SIM card 4 Installation 5 Energiser Configuration 5 Operation 6 SMS Commands 6 PIN 6 Querying the Status 6 Querying the GSM signal 7 Report List 7 Controlling Energi...

Page 4: ...circuit between the input terminals it will register the input as being On Just like the inputs on all JVA Z series devices the input can also be triggered by PLC or alarm panels by connecting the ri...

Page 5: ...nnected devices Connect the DATA and GND terminals to the respective terminals of all connected devices The SMS Gateway requires 12V dc to operate This power may be supplied from the keypad bus of a c...

Page 6: ...t side down with the notched corner to the lower right Clip the circuit board into the case back Connect the antenna Mount the antenna away from high voltage and mains power cables vertically if possi...

Page 7: ...e unit will reply and inform everyone on the report list of the new PIN If you forget the PIN a factory reset must be performed See the section Factory Reset for more information Querying the Status T...

Page 8: ...is supplied the sending number is removed If the parameter is supplied it can be either the number you wish to remove or the position of the number in the report list If entering a number it must be i...

Page 9: ...seconds issue a status command 1234 s The unit will reply with a summary of all connected energisers Next add your number to the report list Send 1234 a The unit will reply with your number has been...

Page 10: ...given index or the specified number from the report list 1234 r 1234 remove 1 1234 r 61412345678 61412345678 has been removed from the report list 1234 r 2 1234 remove 041 234 5678 Number not found in...

Page 11: ...ting into a mobile phone and sending and receiving texts Unit does not respond to SMS Poor signal strength Check antenna connection Move antenna mounting place Unit responds to SMS commands but does n...

Page 12: ...then re apply J4 This will reset the PIN to default clear the report list and clear the memory of seen devices JVA Distributors If you have any questions or need further assistance please email us at...

Reviews: