background image

Installation of the pump JUWEL Eccoflow in the filter system 

 

 

Bioflow Super, 3.0, 6.0, 8.0

 

 

 

Please ensure that the impeller has been properly inserted and the pump adapter has
been firmly connected to the motor prior to the installation of the new pump.

 

 

 

 

Please proceed as follows:

 

 

 

 

1. Disconnect all electrical devices of the aquarium from the power grid.

 

 

2. Remove the outlet nozzles and remove the old pump from the filter.

 

 

3. Insert the new pump into the separation wall of the filter and firmly push it into
place.

 

 

4. Connect the outlet nozzle to direct the waterflow as desired from the outside to the
outlet opening of the pump. Reinstall the gasket into the round opening of the filter
housing when connecting the outlet. This decreases vibration transmissions. 

 

 

 

 

Now the pump is ready for operation and you may reconnect the electrical devices to
the power grid.

 

 

Maintenance of the pump JUWEL Eccoflow in the filter system 

 

 

Bioflow Super, 3.0, 6.0, 8.0

 

 

 

The pump JUWEL Eccoflow should be checked with regard to functionality and cleaned
at regular intervals (at least once a month).

 

 

 

 

Please proceed as follows to that end:

 

 

 

 

1. Disconnect all electrical devices of the aquarium from the power grid.

 

 

2. Remove the outlet nozzles.

 

 

3. Remove the pump from the separation wall of the filter.

 

 

4. Disconnect the adapter (A) from the motor by turning it counter-clockwise and
remove the impeller.

 

 

5. Thoroughly clean all components. It is particularly necessary to remove the impeller
from the chamber and remove deposits and dirt from the chamber itself as well as the
impeller. The function of the pump will be impaired otherwise. Also check the impeller
for damage and possible signs of wear of the magnet. 

 

 

 

 

After that, please reinstall the pump in reverse order in the filter. 

 

 

A

A

Recommendation

 

JUWEL Digital Thermometer 2.0

To monitor the temperature we recommend the JUWEL Digital Thermometer (Part No.
85702). Available from your JUWEL Aquarium retailer.

3

Summary of Contents for Eccoflow 300

Page 1: ...JUWELEccoflow 300 500 600 1000 1500 Typ 280 500 600 1000 1500 Instruction Manual Pump Set www juwel aquarium com ...

Page 2: ...upply before removing it from the filter The power head is intended for indoor use and for use in fluids up to 35 C Never repair the electrical cord or plug In case of damage replace the complete power head Recommendation In order to ensure that the power head operates at its optimum and maintains its low noise level we recommend to check and potentially replace the parts subject to wear and tear ...

Page 3: ...tenance of the pump JUWEL Eccoflow in the filter system Bioflow Super 3 0 6 0 8 0 The pump JUWEL Eccoflow should be checked with regard to functionality and cleaned at regular intervals at least once a month Please proceed as follows to that end 1 Disconnect all electrical devices of the aquarium from the power grid 2 Remove the outlet nozzles 3 Remove the pump from the separation wall of the filt...

Page 4: ...cting the outlet This decreases vibration transmissions Now the pump is ready for operation and you may reconnect the electrical devices to the power grid A C C B Maintenance of the pump JUWEL Eccoflow in the filter system Compact Standard H Jumbo The pump JUWEL Eccoflow should be checked with regard to functionality and cleaned at regular intervals at least once a month Please proceed as follows ...

Page 5: ...repayment of the purchase price 2 Guarantee period and settlement procedure 1 The guarantee period begins on the day of the purchase of the product from the retailer Claims under this guarantee will not be honoured if a the damage is caused as a result of improper use or maintenance or non observance of the instructions given in this manual b the product or its components have been maintained by p...

Reviews: