Juta MPPT-20 User Manual Download Page 2

P/ P

A

 =

P

B

— P

A

/ P

A

32..3% 

As a result of different manufacture of solar panels, different solar illumination intensity, different 

temperature,  different  efficiency  of  solar  charge  controller  and  so  on.  The  effective  power 

increase rate is 10-30%. 

 

Form a complete set:   

Solar Panel: 

12V solar system should  use  40pcs cells laminated solar panel.  The maximum 

power point voltage is18V above. 24V solar system should use 2pcs above mentioned solar 

panels. 48V solar system should use 4pcs above mentioned solar panels. 

Conductor: 

The cable between solar panel with MPPT solar charge controller should be better 

calculated by 1Ampere per 1mm

². 

Solar  Charge  Controller: 

JUTA  brand  MPPT-10  Model  solar  charge  controller  Rated  input 

Ampere  is  20A

30A

.  We  have  12V,  24V  and  48V  three  kinds  of  MPPT  solar  charge 

controllers  (other  specifications  could  be  designed  as  customer  special  request).  Fit  for 

power of solar panels:   

12V 

20—400Wp

600Wp

    24V

40—800Wp

1200Wp

  48V

80-1600Wp (2400Wp) 

 

Connection:  (  As  Picture  3  according  to 

below process)

 

1. 

Connected  the  “+”,  “-”  poles  of  the 

battery  to  the  controller  (  3,  4  from  left) 

firmly  and  correctly.  At  this  time  the 

LOAD green LED is bright. If the LOAD 

green  LED  is  not  bright,  it  is  indicate 

there 

is 

battery 

reverse 

polarity 

connection. 

Only  LOAD  green  LED  is 

bright,  we  could  continue  next  step 

operation. 

2. 

Connected the “+”, “-” poles of the solar 

panel to the controller (1,2 from the left) 

firmly and correctly. 

3. 

Connected the “+”, “-” poles of the LOAD to   

the controller (5,6 from the left) firmly and correctly.                         

Picture 3

 

 

Simply Measure Methord: 

For 12V system, measure the input voltage from solar panel 

with multimeter (terminal 1, 2 of controller), it is normal if the voltage of solar panel more 

than  battery  voltage  0.5-6V.  Generally,  the  higher  input  voltage,  the  better  charge 

efficiency.  For  24v  and  48V  system,  the  input  voltage  will  be  much  more  higher  than 

battery voltage 

(Note: It is normal phenomenon the controller can not find Maximum Power Point within 

10 minutes from system start.) 

Indicator: (Picture 1) 

1.  Load indicator, green, bright indicate there is output, Load could work, “off” indicate 

there is not output, Load can not work. 