LEAK TESTING
NEVER USE A NAKED FLAME TO CHECK FOR LEAKS.
NEVER LEAK TEST WHILE SMOKING.
The gas connections on this appliance are leak tested at the factory prior to
shipment.
This appliance needs to be periodically checked for leaks and an immediate
check is required if the smell of gas is detected.
●
Make a soap solution using 1 part of liquid dish-washing soap to 3 parts
water. The soap solution can be applied with a soap bottle, brush, or rag
to the leak tested points shown in the figure above.
●
The valve of the gas cylinder should be in the
OFF
position at this point of
the leak test. Once the soapy solution is applied to the gas connections,
the valve of the gas cylinder needs to be turned to the
ON
position.
●
Soap bubbles will begin to form in the soapy solution if a leak is present.
●
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and recheck.
GAS REQUIREMENTS
●
The appliance must use an EN12864 or EN16129 approved gas regulator and CE approved gas hose with a
STEP 9:
Fix Rubber Ring (6) into the bottom of Glass Tube (5). Insert the top end of glass tube into the bottom
hole of Flame Screen (2) as much as possible. Keep glass tube vertically and sit it in the hole of Plate Cover (8).
NOTE: GLASS TUBE IS FRAGILE PART, PLEASE HANDLE GLASS TUBE CAREFULLY AND SLOWLY!
STEP 10:
Assemble Mesh Guard (4) in the front.
Loose 4pcs screws to keep 4pcs Guard Fastening
Plates down and firmly in place.
STEP 11:
Insert the feet of door into the bottom slots.
Attach the Chain (7) to the hook of Burner Assembly (9)
and close the door.
Note: Model H1507 doesn’t take this Chain.
!
!
!
!
!
!
!