(P8)
Enable signal
level
(P10)
This parameter is set to control the Enable Input
signal level. 0 means low, while 1 means high.
Edge of the pulse
(P11)
This parameter is set to choice the edge of the input
pulse. 0 means rising edge, while 1 means falling
edge.
Command Type
(P13)
This parameter is set to choice the PUL/DIR mode
or CW/CCW mode. 0 means PUL/DIR mode,while
means CW/CCW mode.
User-defined
micro steps
((P14)
This parameter is set of user-defined micro steps.
The actual micro steps = the set value
×
50. For
example, if the parameter is 4, the micro steps is 4
×
50 =800. But If this parameter is 0, which means
micro steps is set by the outer DIP switches.
Time of
standstill current
(P15)
This parameter is set the time when the standstill
current is set to be half of the selected dynamic
current or other current.
Percentage of
standstill current
This parameter is set the percentage of standstill
current.