1 Preparing and using for the first time
k
T
Press the Rotary Switch.
OPEN TAP
l
T
Turn the switch anticlockwise to position
m
.
FILTER RINSING
, water flows out of
the hot-water nozzle.
E
You can interrupt rinsing of the filter at any
time. To do this, turn the switch clockwise.
Turn the switch anticlockwise to continue
rinsing the filter.
E
The water may be slightly discolored. This is
not harmful to health and does not affect
the taste.
Rinsing of the filter stops automatically,
CLOSE TAP
.
y
T
Turn the switch clockwise to position
o
.
HEATING
READY
The filter is now activated.
Determining and adjusting the water
hardness
E
If you are using the CLEARYL Blue filter
cartridge and have activated it in program-
ming mode, you will not be able to adjust
the water hardness.
The harder the water is, the more frequently the
ENA needs to be descaled. It is therefore important
to adjust the water hardness.
The water hardness can be adjusted on a continu-
ous scale between 1° dH and 30° dH.
Level
Display German
Degree (°dH)
Degrees of general
hardness (°dGH)
Parts per
million (ppm)
Indicator Strip number
of ‘reddish’ fields
Not active
–
–
–
–
Very soft water
<3
<3
< 53.4
None
Soft water
> 4
> 4
> 71
1
Hard water
> 8.4
> 8.4
> 150
2
Very hard water
> 14
> 14
> 250
3