12
operation and good performance of the unit.
— The best performance of the unit is obtained
in the exhaust mode, therefore in the limits
of the possibilities it is advised to use the
cooker hood in this way.
— The best performances are obtained with
short pipes and with few curves.
— In order to eliminate loss of heat towards the
outside; in the winter period the unit can be
used in the recycling (filtering) mode.
— In the event of fire, disconnect immediately
the unit from the power supply remove the
source of fire (pots, etc.).
Installation
- Fig. 4
When installed, the distance between hood
and burners must be not less than 65 cm.
above electric burners or 75 cm. above gas or
mixed-fuel burners.
Electric connection
Before completing any connection, make sure
the house voltage corresponds with the voltage
indicated on the label affixed inside the hood
It is advisable to call a qualified technician to
make the electrical connection.
Appliance fitted with plug.
Connect it to a socket which conforms with
current regulations.
If you intend to connect it directly to the electric
mains, remove the plug and fit an approved
bipolar switch with a minimum contact opening
of no less than 3mm.
If the plug is not accessible once it has been
inserted in the socket, it will however be
necessary to fit an approved bipolar switch with
a minimum contact opening of no less than
3mm.
Appliance without plug
Fit an approved plug or an approved bipolar
switch with a minimum contact opening of not
less than 3mm.
The manufacturers are not liable for any
problems caused by the user’s failure to
observer the above instructions.
Systems available
Two systems are available:
Exhaust mode
Vapours are extracted outside through an
exhausting pipe that is affixed to the connection
ring above the hood (Fig. 1,A).
Diameter of the exhausting pipe must be equal
to that of the connection ring.
In the horizontal runs the duct must be slightly
slanted (about 10°) and directed upwards to
vent the air easily from the room to the outside.
Attention!
If the hood is supplied with carbon filter,
then it must be removed.
Recirculation mode
(K - See the installation diagram)
The air is filtered through a carbon filter and
recirculated into the room through the grid on
the higher part of the chimney.
Attention!
If the hood is not supplied with carbon filter,
then it must be ordered and mounted.
Fastening of shelves (optional)
Fasten the four side supports I to the adjacent
cabinets and place the shelf on the supports
(Fig. 5).