Chapter 3 Configuring the Device
12
User’s Guide
E
STABLISHING
A
C
ONSOLE
S
ESSION
The NetScreen-5XT has a serial port (called the Console port) that enables you to
establish a console session with NetScreen ScreenOS, the device operating system.
To establish a console session:
1.
Plug the female DB-9 end of the serial cable into the serial port of your
computer. (Be sure that the DB-9 clip is seated properly in the port.)
2.
Plug the male DB-9 end of the serial cable into the Console port of the
NetScreen-5XT. (Be sure that the DB-9 is seated properly in the port.)
3.
Launch a serial terminal program. (A commonly-used terminal program is
Hilgraeve HyperTerminal.) Typical settings to launch a console session with
your NetScreen-5XT are as follows:
• Baud Rate to 9600
• Parity to No
• Data Bits to 8
• Stop Bit to 1
• Flow Control to none
4.
At the login prompt, type
netscreen
.
5.
At the password prompt, type
netscreen
.
C
HANGING
Y
OUR
A
DMIN
N
AME
AND
P
ASSWORD
Because all Juniper Networks NetScreen products use the same admin name and
password (netscreen), it is highly advisable to change your admin name and password
immediately. Enter the following commands:
set admin name
name_str
set admin password
pswd_str
save
For information on creating different levels of administrators, see “Administration” in the
NetScreen Concepts & Examples ScreenOS Reference Guide.
Note:
For the console connection, you will need to obtain a serial cable with a male DB-9
connector on one end and female DB-9 connector on the other wired straight-through cable.
Note:
Both login and password are case-sensitive.