background image

M5 and M10 Internet Backbone Routers

M 5   a n d   M 1 0   R o u t e r s   P o w e r   S u p p l y   S p e c i f i c a t i o n s

Specification

AC

DC

Maximum power consumption

434 W

434 W

Input voltage

100 through 264 VAC operating range

–42.5 through –72 VDC operating range

Input line frequency

47 through 63 Hz, autoranging

Input current rating

8 A @ 100 VAC; 4 A @ 240 VAC

13.5 A @ –48 VDC (typical)

Output voltages

+1.5 V; +2.5 V; +3.3 V; +5 V; +12 V

+1.5 V; +2.5 V; +3.3 V; +5 V; +12 V

Power and grounding cords and cables

Country-specific; see 

M5 and M10 Internet

12 AWG wire cables attaching to

Backbone Router Hardware Installation Guide

quick-connect terminals; grounding
cable attaches to single-hole cable lug

M 5   a n d   M 1 0   R o u t e r s   L E D s

Component

LED

Location

PICs

1 LED per port, with 4 states: Red, Green, Amber, Off

PIC faceplate

Power supplies

Blue OUTPUT OK

Power supply faceplate

Alarm LEDs

Red alarm

Large circular red

Craft interface

Yellow alarm

Large triangular amber

Craft interface

Red alarms occur when the router is started if no device is physically connected to the management 

fxp0

 interface or if two power supplies are

physically installed but only one is switched on.

Ta k i n g   C o m p o n e n t s   O f f l i n e

Component

Procedure

PIC

1. Press the PIC offline button, located on the PIC faceplate.
2. Press and hold the button until the PIC LED lights red (about 5 seconds).
3. Press and hold the offline button again after installing the replacement PIC to bring the PIC online.

Summary of Contents for M10

Page 1: ...uter components Yes Hot removable 3 fans Hot insertable Craft interface 1 Displays status and allows you to take PICs offline Hot removable and hot insertable Can remove and replace without powering down the router or disrupting routing functions Hot pluggable Can remove without powering down the router but the routing and forwarding functions are interrupted until the replacement component is ins...

Page 2: ...nding cable attaches to single hole cable lug M5 and M10 Routers LEDs Component LED Location PICs 1 LED per port with 4 states Red Green Amber Off PIC faceplate Power supplies Blue OUTPUT OK Power supply faceplate Alarm LEDs Red alarm Large circular red Craft interface Yellow alarm Large triangular amber Craft interface Red alarms occur when the router is started if no device is physically connect...

Page 3: ... as well as processes controlling interfaces router components system management and user access These processes run on top of a kernel that interacts with the Packet Forwarding Engine Control Packet Handling The Routing Engine constructs and maintains routing tables and derives a table of active routes called the forwarding table from the routing tables The forwarding table is then copied into th...

Page 4: ...s in wet locations unless the jacks are specifically designed for wet environments Operate the router only when the grounding wire is connected Use copper conductors only Avoid touching uninsulated electrical wires or terminals that have not been disconnected from their power source Doing so could cause electrical shock Do not open or remove chassis covers or sheet metal parts when instructions ar...

Reviews: