Copyright © 2010, Juniper Networks, Inc.
Errata
57
Release 11.1.1
z
ERX Module Guide, Appendix A, Module Protocol Support
incorrectly states that IPv6
multicast is supported on the following line modules:
−
cOCx FO line module with cOC3/STM1 modules
−
cOCx FO line module with cOC12/STM4 FO I/O modules
−
COCx-F3 line modules with CT3/T3 12 I/O modules
−
OCx/STMx ATM line modules with 4xDS3 ATM I/O modules
−
CT3/T3-FO line modules with CT3/T3 12 I/O modules
z
E120 and E320 Module Guide, Appendix A, IOA Protocol Support
incorrectly states that
IPv6 multicast is supported on the ES2-S1 Service IOA module. IPv6 multicast is not
supported on this module.
z
The
Detecting Corrupt File Configurations
section in
JunosE System Basics
Configuration Guide, Chapter 5, Managing the System
fails to mention that if you
check the running configuration for corruption manually when auto mode is enabled,
a warning message appears:
host1(config)#
service check-config running-configuration
WARNING: This command will cause config monitor to switch into manual mode.
Proceed with current command? [confirm]
If you confirm you want to check the running configuration in manual mode or press
any key to continue, then manual mode is enabled.
z
In
JunosE IP, IPv6, and IGP Configuration Guide, Chapter 2, Configuring IPv6
, the
Before
You Configure IPv6
section fails to list all the modules that support IPv6. You can find
complete lists of modules that support IPv6 in the following appendixes:
−
E120 and E320 Module Guide, Appendix A, IOA Protocol Support
−
ERX Module Guide, Appendix A, Module Protocol Support
z
In the
Configuring Graceful Restart
section in
JunosE IP, IPv6, and IGP Configuration
Guide, Chapter 6, Configuring IS-IS
, the default time for the restarting router to wait
for the LSP database to synchronize and to reset the overload bit is incorrectly
mentioned as 30 seconds. The correct value is 100 seconds for both the instances.
cOC12/STM4multimode without
APS/MSP redundancy
ERX
cOC12/STM4 single-mode intermediate
reach without APS/MSP redundancy
ERX
cOC12/STM4 single-mode intermediate
reach with APS/MSP
redundancy
ERX
cOC12/STM4 single-mode long reach
ERX
CT3/T3 12 (12 ports)
ERX
E3 Frame (12 ports)
ERX
IPSec Service Module
ERX
SRP 5G+(2 GB)
ERX
T3 Frame (12 ports)
ERX
10GE IOA
E120 and E320
Module Name
Module Type