Known Problems and Limitations
51
Release 10.2.2
System
You cannot use a configuration script to boot the E320 router. [Defect ID
80304]
If you hot swap an IOA and then remove it again before that IOA’s OK or FAIL
LED is illuminated, the associated line module can reset. [Defect ID
177313/177267]
Work-around
: Ensure that you firmly insert the IOA into the chassis when you
hot swap IOAs. Do not attempt a second hot swap of an IOA that has not
indicated that it completed the first hot swap cycle. You can remove the IOA
when either its OK or FAIL LED is illuminated.
If your router is in Manual Commit mode, then you must issue the
write
memory
command before you perform an SRP module switch or a manual
reload. You must do this even when you have made no changes to the system
configuration and the file systems are synchronized. [Defect ID 44469]
System Logging
The
show configuration category management syslog virtual-router default
command incorrectly displays logs for multiple syslog destinations when you
add a log to only one syslog destination. The
show log configuration
command shows the correct configuration. [Defect ID 84082]
TCP
The SRP module resets in any of the following circumstances on an E320 router
that has a line module configured with 5000 ANCP adjacencies: [Defect ID
176916]
When you issue the
issu initialization
command from the console and
then reload the line module from a Telnet session.
When the client that has the 5000 ANCP clients resets or an intermediate
switch resets.
When you reload the line module.
Unified ISSU
ATM line modules might reset after a unified ISSU when you attempt to add
memory to a VLAN subinterface in a large bridged Ethernet configuration.
[Defect ID 178798]
Under certain conditions, a unified ISSU from JUNOSe Release 9.2.0p1-0 to the
current release fails, and causes the SRP module and the ES2 4G LM to reset.
[Defect ID 179975]
Unified ISSU is not supported with 8000 bridged Ethernet interfaces on an
OC3/STM1 GE/FE ATM line module. [Defect ID 178809/178811/178797/
179547]