SEE ALSO
Field-Replaceable Units on the JSA5800 Appliance | 0
Contacting Juniper Networks Technical Assistance Center | 49
Replacing DC Power Supply Cables on the JSA5800 Appliance | 0
Replacing DC Power Supply Cables on the JSA5800 Appliance
To replace a DC power supply cable connected to a JSA5800 appliance:
1. Attach an ESD grounding strap to your bare wrist and connect the strap to one of the ESD points on
the chassis.
2. Switch off the external circuit breakers for all the cables attached to the power supply. Make sure
that the voltage across the DC power source cable leads is 0 V and that there is no chance that the
cables might become active during the removal process.
3. Remove the clear plastic cover over the terminal studs on the faceplate.
4. Remove the power cable from the DC power source.
NOTE: Ensure the cable is not touching or in the way of any components, and that it does not
drape where people could trip on it.
5. Attach the power cable to the DC power source. For more information, see
Connecting the JSA5800
to Power
.
6. Replace the clear plastic cover over the terminal studs on the faceplate.
7. If the power supply is correctly installed and functioning normally, the supply automatically powers
up.
SEE ALSO
Field-Replaceable Units on the JSA5800 Appliance | 0
Contacting Juniper Networks Technical Assistance Center | 49
Replacing a DC Power Supply on the JSA5800 Appliance | 0
RELATED DOCUMENTATION
Connecting the JSA5800 to Power | 32
46
Summary of Contents for JSA5800
Page 1: ...Juniper Secure Analytics 5800 Hardware Guide Published 2021 06 03...
Page 7: ...1 CHAPTER Overview JSA5800 System Overview 2 JSA5800 Chassis 4...
Page 25: ...JSA5800 Chassis 4 JSA5800 Installation Overview 21 19...
Page 53: ...JSA5800 Chassis 4 47...
Page 54: ...5 CHAPTER Troubleshooting Hardware Contacting Juniper Networks Technical Assistance Center 49...