Table 29: EX Series Switch Environmental Tolerances
(continued)
Environment Tolerance
Switch or
device
Seismic
Temperature
Relative Humidity
Altitude
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
•
Normal operation ensured in
temperature range of 32° F
through 104° F (0° C through
40° C)
•
Nonoperating storage
temperature in shipping
container: –40° F through
158° F (–40° C through 70° C)
Normal operation ensured in
relative humidity range of
5% through 90%,
noncondensing
•
Short-term operation
ensured in relative
humidity range of 5%
through 93%,
noncondensing
NOTE:
As defined in
NEBS GR-63-CORE, Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
No performance
degradation to
6,562 feet
(2000 meters)
EX4600
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX6210
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX8208
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Normal operation ensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operation ensured in
relative humidity range of
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX9204
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation ensured in the
temperature range 32° F through
104° F (0° C through 40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operation ensured in
relative humidity range of
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX9208
83
Copyright © 2015, Juniper Networks, Inc.
Chapter 4: Site Preparation
Summary of Contents for EX4500-40F-BF
Page 12: ...Copyright 2015 Juniper Networks Inc xii Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 20: ...Copyright 2015 Juniper Networks Inc 2 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 92: ...Copyright 2015 Juniper Networks Inc 74 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 94: ...Copyright 2015 Juniper Networks Inc 76 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 108: ...Copyright 2015 Juniper Networks Inc 90 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 112: ...Copyright 2015 Juniper Networks Inc 94 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 128: ...Copyright 2015 Juniper Networks Inc 110 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 172: ...Copyright 2015 Juniper Networks Inc 154 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 186: ...Copyright 2015 Juniper Networks Inc 168 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 188: ...Copyright 2015 Juniper Networks Inc 170 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 216: ...Copyright 2015 Juniper Networks Inc 198 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 218: ...Copyright 2015 Juniper Networks Inc 200 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 222: ...Copyright 2015 Juniper Networks Inc 204 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 226: ...Copyright 2015 Juniper Networks Inc 208 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 236: ...Copyright 2015 Juniper Networks Inc 218 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 238: ...Copyright 2015 Juniper Networks Inc 220 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 250: ...Copyright 2015 Juniper Networks Inc 232 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 266: ...Copyright 2015 Juniper Networks Inc 248 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 284: ...Copyright 2015 Juniper Networks Inc 266 Complete Hardware Guide for EX4500 Ethernet Switches ...
Page 286: ...Copyright 2015 Juniper Networks Inc 268 Complete Hardware Guide for EX4500 Ethernet Switches ...