ACX2000 and ACX2100 Alarm, Management, and
Clocking Cable Specifications and Pinouts
IN THIS SECTION
Alarm Contact Port Pinouts on the ACX2000 and ACX2100 Router | 85
Management Port Connector Pinout Information for ACX Series Routers | 87
Console or Auxiliary Port Connector Pinout on ACX Series Routers | 88
USB Port Specifications for an ACX Series Router | 89
Clocking Ports Specifications on the ACX2000 and the ACX2100 Router | 89
Alarm Contact Port Pinouts on the ACX2000 and ACX2100 Router
You can independently configure alarm input ports (0 to 3) to operate in Normally Open or Normally Closed
mode, and to trigger a red alarm condition or a yellow alarm condition, or to ignore alarm conditions.
You can independently configure alarm output ports (0 and 1) can be configured to relay alarm information
when the system condition goes to a red or yellow alarm condition and when the alarm output port is
configured to trigger based on alarm input condition. Alarm output ports (2 and 3) are used to indicate
major and minor system alarms and are normally in open mode.
shows the alarm contact connector pinouts.
Table 29: Alarm Contact Connector Pinouts
Function
CLI Port Mapping
Direction
Signal Definition
Pin
Number
External alarm input 0 (if voltage on this
pin is between 24V to 72V with reference
to Pin 6, alarm input 0 is in closed
condition)
Input Alarm Port 0
Input
ALARM_IN0_NO/NC
1
External alarm input 1 (Reference for Pin
7)
Input Alarm Port 1
Input
ALARM_IN1_REF
2
85
Summary of Contents for ACX2000
Page 1: ...ACX2000 and ACX2100 Universal Metro Router Hardware Guide Published 2020 09 07 ...
Page 91: ...Front Panel of an ACX2000 Router 47 LEDs on ACX2000 and ACX2100 Routers 57 91 ...
Page 116: ...4 CHAPTER Maintaining Components Maintaining ACX2000 and ACX2100 Components 117 ...
Page 125: ...5 CHAPTER Troubleshooting Hardware Troubleshooting ACX2000 and ACX2100 126 ...
Page 139: ...139 ...
Page 144: ...Restricted Access Warning 144 ...
Page 148: ...148 ...
Page 161: ...Jewelry Removal Warning 161 ...
Page 164: ...Operating Temperature Warning 164 ...
Page 174: ...DC Power Disconnection Warning 174 ...
Page 178: ...DC Power Wiring Sequence Warning 178 ...