JNR MINI BEAM 230

JNR-8129

PR LIGHTING LTD.

http://www.pr-lighting.com

1582 Xingye Avenue, Nancun Panyu

Guangzhou, 511442 China

TEL: +86-20-3995 2888

Summary of Contents for JNR mini-beam 230

Page 1: ...JNR MINI BEAM 230 JNR 8129 PR LIGHTING LTD http www pr lighting com 1582 Xingye Avenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 ...

Page 2: ...ay arise This is a normal process and does not necessarily mean that the device is defective it should decrease gradually Please don t project the beam onto combustible substances Fixtures cannot be installed on combustible substances keep more than 50cm distance with wall for smooth air flow so there should be no shelter for fans and ventilation for heat radiation If the external flexible cable o...

Page 3: ...during the inspection 1 All screws for installing the devices or parts of the device have to be tightly connected and must not be corroded 2 There must not be any deformations on the housing color lenses fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables m...

Page 4: ...IN OUT Fan cooling system Constant temperature readout and management function Lamp using time readable on the display 35 45 C max ambient temperature IP20 protection rating 55dB at 3 dB rating 2 1 4 turn fastening Omega clamps 1 Safety attachment point available OSRAM 16 facet prism with 11 colors plus open 6 facet 8 facet prism with variable speed and direction Combined prism effect by 16 facet ...

Page 5: ... Gobo 4 shake slow to fast Gobo 5 shake slow to fast Gobo 6 shake slow to fast Gobo 7 shake slow to fast Gobo 8 shake slow to fast Gobo 9 shake slow to fast Gobo 10 shake slow to fast Gobo 11 shake slow to fast Gobo 12 shake slow to fast Gobo 13 shake slow to fast Gobo 14 shake slow to fast Gobo 15 shake slow to fast Gobo 16 shake slow to fast Rot gobo wheel cont rotation slow to fast Shutter clos...

Page 6: ...ion It s recommended to replace the units if MINI BEAM 230 2 5 Beam Angle LUX 0 0929 FC Photometric Beam Angle Data ø 0 54 ø 1 77 ø 1 06 ø 3 48 Beam Diameter m ft ø 0 8 ø 2 62 0m 2 5 10m 32 8ft FC LUX 163200 72000 39600 20m 65 6ft 15m 49 2ft DMX CHANNELS 9 10 0 255 0 255 0 255 0 255 0 4 5 9 10 14 15 19 20 24 25 29 30 34 35 39 40 44 45 49 50 54 55 59 60 64 65 69 70 74 75 79 80 84 85 89 90 94 95 99 ...

Page 7: ... including amongst others calculating working load limits a fine knowledge of the installation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the mai...

Page 8: ... Turn Quick Lock Fasteners 1 4 Turn 1 4 Turn 08 Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connecti...