1004
.GB
E 8
4.5
Troubleshooting
This chapter allows the user to identify and rectify basic faults or the effects of
incorrect operation. When trying to locate a fault, proceed in the order shown in the
table.
Z
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer’s service organisation, as any further troubleshooting can only be
performed by specially trained and qualified service personnel.
Fault
Probable Cause
Action
Truck does not
start
– Battery connector not plugged
in
– Check battery plug and plug in
if necessary.
– Key switch set to OFF
– Set key switch to "I"
– Battery still being charged
– Disconnect the 230 volt
connection
– Battery charge too low
– Check battery charge, charge
battery if necessary
– Battery not charging
– Check charger, check battery
terminal connections
– Faulty fuse
– Check fuses 2F1 and F1
Load cannot
be lifted
– Truck not operational
– Carry out all remedial actions
listed under “Truck does not
start”.
– Hydraulic oil level too low
– Check the hydraulic oil level
– Faulty fuse
– Check fuse F1
– Load is too heavy
– Note maximum capacity (see
data plate)
– Charge capacity below 40%
– Charging the battery
1004
.GB
E 8
4.5
Troubleshooting
This chapter allows the user to identify and rectify basic faults or the effects of
incorrect operation. When trying to locate a fault, proceed in the order shown in the
table.
Z
If the fault cannot be rectified after carrying out the remedial procedure, notify the
manufacturer’s service organisation, as any further troubleshooting can only be
performed by specially trained and qualified service personnel.
Fault
Probable Cause
Action
Truck does not
start
– Battery connector not plugged
in
– Check battery plug and plug in
if necessary.
– Key switch set to OFF
– Set key switch to "I"
– Battery still being charged
– Disconnect the 230 volt
connection
– Battery charge too low
– Check battery charge, charge
battery if necessary
– Battery not charging
– Check charger, check battery
terminal connections
– Faulty fuse
– Check fuses 2F1 and F1
Load cannot
be lifted
– Truck not operational
– Carry out all remedial actions
listed under “Truck does not
start”.
– Hydraulic oil level too low
– Check the hydraulic oil level
– Faulty fuse
– Check fuse F1
– Load is too heavy
– Note maximum capacity (see
data plate)
– Charge capacity below 40%
– Charging the battery
Summary of Contents for HC 110
Page 1: ...Operator Manual 51017163 HC 110 G 12 05 07 08 ...
Page 3: ...0108 GB 0108 GB ...
Page 7: ...1004 GB A 2 1004 GB A 2 ...
Page 12: ...B 5 1004 GB B 5 1004 GB ...
Page 17: ...1004 GB B 10 1004 GB B 10 ...
Page 25: ...1004 GB D 6 1004 GB D 6 ...
Page 28: ...E 3 1004 GB 1 2 3 4 5 6 7 8 9 10 11 E 3 1004 GB 1 2 3 4 5 6 7 8 9 10 11 ...