background image

 

26 

 
 
 

Ring tone volume / Ring tone OFF/ON 

 

 

 
 
 
 
 
 
 
 

 

 
 
 
 

 

 

The ring tone volume is adjustable in 5 levels:  
1, 2, 3, 4 and OFF (ring tone is switched OFF). 
 

  Push ring tone button (approx. 1 s). 

 

  You can hear the adjusted ring tone 

 

  Now the volume is one level louder  

 

Repeat the action as long as the desired volume is  
reached. 
 

 

 

 
 
 
       

 

 

 

Ring tone OFF: 
 

  Repeat the action until the level OFF is adjusted.  

The LED of the ring tone button is ON. 
 

Push the button again to turn the ring tone ON. 
 

 

Functions of the function button 

 

 

 
 

 
 
 
 
 
 
 
 
 

 

Short push of the function button (max. 1 s). 
Depending on the set function the indoor station indicates 
the action with visual or acoustic signals: 
 

 

 

 

Light switching 

- - 

Internal call 

9

 

flashing 

Call diversion ON 

9

 

Call diversion OFF 

- - 

Automatic door release ON 

9

 

Automatic door release OFF 

- - 

 

 
 

Summary of Contents for TK IS A 514 A Series

Page 1: ...ation DCM Standard indoor stations TK IS A 514 A TK IS A 514 AD Design ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle Phone 49 2355 806 0 Fax 49 2355 806 189 E Mail mail info jung de Intern...

Page 2: ...the device settings 11 Factory settings 11 Function button 12 Setting of function button Internal call call diversion door release function and control function 12 Light switching 15 Reloading the fa...

Page 3: ...rements of DIN VDE 0100 must be observed When installing DCM BUS systems the general safety rules for telecommunication systems in accordance with VDE 0800 must be observed separate cabling for high a...

Page 4: ...ge over between speaking listening if simplex communication is activated Selection of 13 ring tones ring tone differentiation between main door floor door and internal call sub door call 4 bell button...

Page 5: ...unction button Activation of the assigned function Initiate the setting mode of the function button Indication LED on Call diversion or automatic door release is activated Door release button Activati...

Page 6: ...cable length and loop resistance No illumination of indoor station in 2 wire installations possible Slide switch in position II Floor bell button Floor bell button Indoor station Indoor station Outdo...

Page 7: ...wire operation 3 wire operation 3 wire technique Please observe cable length and loop resistance Slide switch in position III Floor bell button Floor bell button Indoor station Indoor station Outdoor...

Page 8: ...connection holes 1 can be used to connect an indoor station with design frame onto a wall box with hole centre distance of 60 mm Connecting wires Type of cable Telecommunication cable J Y St Y with t...

Page 9: ...ide 2 wire operation 3 wire operation Assembling device Device without design frame A Put the top device onto the snap connectors 4 of the bottom shell and press until you can here a snap on sound Dev...

Page 10: ...ndoor station is a squared slot to unlock and open the device Insert a screwdriver approx 7mm with slight pressure straight into the slot 2 The device can be pulled at the lower side out of the shell...

Page 11: ...an EEPROM After mains voltage failure following remains saved in the EEPROM Selected ring tone ring tone volume mute activated call diversion internal call automatic door release control functions an...

Page 12: ...8 s until you can hear acknowledge tone fast LED flashing release the function button All LED flashing fast Push communication button acknowledge tone End of settings The device switches into idle mod...

Page 13: ...the function button All LED flashing fast push communication button acknowledge tone End of settings The device switches into idle mode All LEDs OFF Target indoor station IS2 If green LED is illumina...

Page 14: ...l you can hear acknowledge tone fast LED flashing release the function button All LED flashing fast push door release button acknowledge tone End of settings The device switches into idle mode all LED...

Page 15: ...eans of pushing the function button Light switching Resetting the function button to the function light switching takes place by means of reloading the factory settings Reloading the factory settings...

Page 16: ...the IS 228515 With the following key combination IS 228520 operates parallel with IS 228515 99 228520 228515 Note Deleting the parallel function with ParSNr 0 99 228520 0 Ser Nr Serial number of the...

Page 17: ...e button Ring tone volume Ring tone OFF ON The ring tone volume is adjustable in 5 levels 1 2 3 4 and OFF ring tone is switched OFF Push ring tone button approx 1 s You can hear the adjusted ring tone...

Page 18: ...ntil you can hear acknowledge tone fast LED flashing release the ring tone button All LED flashing fast Push door release button You can hear the next ring tone All LEDs are ON for the time of the rin...

Page 19: ...ashing release the ring tone button All LED flashing fast Push communication button You can hear the next ring tone All LEDs are ON for the time of the ring tone then flashing fast again The last audi...

Page 20: ...e the ring tone button All LED flashing fast Push ring tone button You can hear the next ring tone All LEDs are ON for the time of the ring tone then flashing fast again The last audible ring tone is...

Page 21: ...g fast Push function button You can hear the next ring tone All LEDs are ON for the time of the ring tone then flashing fast again The last audible ring tone is selected for the floor bell button Repe...

Page 22: ...cknowledge tone continue pushing After further 4 s you can hear a second acknowledge tone LED pulse flashing release the ring tone button Now the indoor station is ready for the following assignment S...

Page 23: ...can hear the next ring tone All LEDs are ON for the time of the ring tone then pulse flashing again The last audible ring tone is selected for the sub door call 3 Repeat the action until the desired...

Page 24: ...ommunication Loud and abnormal backround noise disturb the proper function of the communication Deactivation of the hands free operation is recommended During an existing communication push the commun...

Page 25: ...off Door release Push the door release button to open the door When light switching function is activated Push communication button Push the door release button to open the door Light switching Push...

Page 26: ...me is reached Ring tone OFF Repeat the action until the level OFF is adjusted The LED of the ring tone button is ON Push the button again to turn the ring tone ON Functions of the function button Shor...

Page 27: ...tching factory setting A bell button of the outdoor station will switch the light if the bell button is not assigned to an indoor station Light switching function Programming at the power supply and c...

Page 28: ...talking time 60 s factory setting The talking time is adjustable Control function Command for the control of various relays in the door communication system Sub door call Programming only with the se...

Page 29: ...doubled i e two lines are used for one wire figure The lines must be twisted When using screened cables connect the screens to each other and connect on one side to earth b wire on the power supply un...

Page 30: ...control unit Technical data Supply voltage 24 V DC 8 Power supply control unit 24 V a b 26 V P b in idle state Dimensions W x H x D 58 x 129 x 21 mm Input current 2 wire I a 2 6 mA in idle state Max i...

Page 31: ...44532 L nen Germany Service Line 0 23 55 80 65 51 Fax 0 23 55 80 61 89 E Mail mail vka jung de Technique DCM Service Line 0 23 55 80 65 52 Fax 0 23 55 80 62 55 E Mail mail vka jung de Albrecht Jung G...