background image

 

KNX 

4-channel analog input module 

 

Ref.-no.: 2214 REG AM 

 

Connection to a KNX/EIB analog input: 

The parameters to be set for connected sensors must be determined 
beforehand. 

Type  

Use  

Order no. 

Brightness 

outdoor  

WS 10H 

Twilight  

outdoor  

WS 10D 

Temperature  

outdoor  

WS 10T 

Wind  

outdoor  

WS 10W 

Rain  

outdoor  

WS 10R 

9. Technical 

Data 

Power supply 
Supply voltage :  

AC 24 V ± 10 % 

Current consumption :  

170 mA max. 

Current consumption 
on system connector :  

typically 150 mW 

Ambient temperature : 

-5 °C ... +45 °C 

Storage/transport temp. :  

-25 °C ... +70 °C 

Humidity 
Ambient/storage/transport :  

93 % r.h. max., no 

 condensation 
Protective system :  

IP 20 as per EN 60529 

Installation width :  

4 modules / 72 mm 

Weight :  

approx. 150 g 

Connections 
Inputs, power supply :  

screw terminals 

single-wire :  

0.5 mm²

 

to 4 mm²

 

stranded wire (without ferrule) :  

0.34 mm²

 

to 4 mm²

 

stranded wire (with ferrule) :  

0.14 mm²

 

to 2.5 mm²

 

Connection to KNX/EIB device : 6-pole system connector 
Sensor inputs 
Number :  

4x analog 

Evaluable sensor signals :  

0 … 1 V DC, 0 … 10 V DC, 

 

0 … 20 mA, 4 … 20 mA 

Voltage measurement impedance :  

approx. 18 k

 

Current measurement impedance :  

approx. 100 

 

External sensor power supply (+U

s

) :  

24 V DC, 100 mA max. 

Subject to technical modifications. 

 

Summary of Contents for KNX 2214 REG AM

Page 1: ...rresponding terminals of another device Connected sensors must not be supplied with power from the connected KNX EIB device Risk of irreparable damage 2 Function This analog input module extends a KNX EIB weather station Art no 2224 REG W or a KNX EIB analog input Art no 2114 REG A by four additional sensor inputs for analog transducers Measuring data evaluation and limit processing take place in ...

Page 2: ...e provided in duplicate and internally interconnected The total current consumption of all sensors supplied this way must not exceed 100 mA In the event of overload or short circuit between US and GND the power will be switched off After removal of the fault the power is switched on again automatically Sensors connected can also be supplied externally e g if their current consumption exceeds 100 m...

Page 3: ...les without adapting their project configuration and subsequent downloading into the KNX EIB device is not allowed as this will result in system failure 7 Status LED During commissioning of the module On Module ready for operation self test OK Quickly blinking Module initialization in progress Slowly blinking Module not configured in KNX EIB device Off Module initialized and in operation Precondit...

Page 4: ...C Storage transport temp 25 C 70 C Humidity Ambient storage transport 93 r h max no condensation Protective system IP 20 as per EN 60529 Installation width 4 modules 72 mm Weight approx 150 g Connections Inputs power supply screw terminals single wire 0 5 mm to 4 mm stranded wire without ferrule 0 34 mm to 4 mm stranded wire with ferrule 0 14 mm to 2 5 mm Connection to KNX EIB device 6 pole system...

Page 5: ...T JUNG GMBH CO KG Service Center Kupferstr 17 19 D 44532 Lünen Service Line 49 0 23 55 80 65 51 Telefax 49 0 23 55 80 61 89 E Mail mail vki jung de Technik allgemein Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 E Mail mail vkm jung de Technik KNX EIB Service Line 49 0 23 55 80 65 56 Telefax 49 0 23 55 80 62 55 E Mail mail vkm jung de The Sign is a free trade sign addressed exclusiv...

Reviews: