Page 1: ...1 Funk W chter 180 Radio Detector 180 Draadloze detector 180 Art Nr FW 180 WW Bedienungsanleitung Operating Instructions Bedieningshandleiding 325 197 03 05 03 J 0082519703 Funk Management...
Page 2: ...8 Acceptance of guarantee 31 Inhoudsopgave 1 Functie 5 2 Montage 9 3 Instellingen 17 4 Inbedrijfstelling 19 5 Standaardbedrijf 23 6 Technische gegevens 27 7 Storingsanalyse 29 8 Garantie 31 Inhaltsver...
Page 3: ...actor zie bedienings handleiding Draadloze actor Bij gebruik van een draadloze vermogensopvoereenheid als ontvanger kan zowel de inschakelduur als de helderheidswaarde bij onderschrijding waarvan het...
Page 4: ...shades of gray in the figure show the 3 detection levels The 3 detection levels are defined as follows Fig e Near range approx 0 m 3 m Center range approx 3 m 9 m Far range approx 9 m 16 m The indica...
Page 5: ...mals bushes moving in the wind passing vehicles or lamps inside the detection range of the sensor If necessary the detection range of the radio detector must be restricted with the snap on lens mask s...
Page 6: ...the condensed water drain hole Fig i c leave closed when fitting the unit in dusty rooms To install the radio detector fix the connection box of the sensor with 2 screws Fig j For installation of the...
Page 7: ...schakeling nood alarm Hetzendbereikvaneendraadlooszend systeemisafhankelijkvanhetvermogen van de zender de ontvangstkarakte ristiek van de ontvangers de lucht vochtigheid de montagehoogte en de bouwte...
Page 8: ...n Germany is subject to the relevant regulations Amts blatt Vfg 73 2000 If utilized in conformity with its designated use this unit fulfills the requirements of the R TTE Directive 1999 5 EC The compl...
Page 9: ...ecessary to tilt the sensor head The angle of turn Fig m c and tilt Fig m d is marked on a scale on the radio detector housing so that the desired position can easily be reproduced Sensitivity The sen...
Page 10: ...field Fig p c blanked out area Fig p d controlled area Blanking out the far field To blank out the far field cut out only the lower half of the lens masking strips Abb q c blanked out area Abb q d co...
Page 11: ...a receiver A radio detector can be used with any number of radio receivers Programming of the sensor concerns exclusively the receiver Programming 1 Switch the radio receiver into the learning mode se...
Page 12: ...1s on low bat 1s on 1s on 5 2 Radio Detector functions Test operation The test mode of the radio detector is activated exclusively after connecting the battery Fig u d for a period of approx 15 minute...
Page 13: ...ceeds a value of 200 lux the sensor switches over to daytime operation The lockout time is approx 8 s during which the sensor cannot detect any movement Low battery voltage When the battery voltage dr...
Page 14: ...100 m free field Transmit codes 1 bn Detection Detection radius 16 m Detection field 180 Installation height approx 2 40 m Sensitivity 20 100 Evaluation Operating range 3 200 lux 50 Sensor normal oper...
Page 15: ...operation not yet elapsed abt 1 minute Battery exhausted red LED in Radio Power Boost Unit lit up Check battery and replace if voltage is too low UBat 7 5 V Radio detector permanently responding Sens...
Page 16: ...Service Center Kupferstr 17 19 D 44532 L nen Service Line 49 0 23 55 80 65 53 Telefax 49 0 23 55 80 61 65 E Mail mail vka jung de Technische dienst algemeen Service Line 49 0 23 55 80 65 55 Telefax 49...
Page 17: ...32 ALBRECHT JUNG GMBH CO KG Volmestra e 1 58579 Schalksm hle http www jung de...