o
Switch the actuator to programming mode (see actuator instructions).
o
Press the
Prog
(figure 2) button for longer than 4 seconds.
Status LED (1) flashes red. The hand-held transmitter is in programming mode for approx.
1 minute.
o
Press button briefly
The status LED lights up for approx. 5 seconds, and the hand-held transmitter is connected
to the actuator. The hand-held transmitter and actuator exit the programming mode
automatically.
i
If the status LED of the radio transmitter flashes 3 times at 1-second intervals for approx.
5 seconds, then the programming operation was not successful. The actuator is outside
radio range, not in programming mode or there are radio faults.
i
If the status LED of the actuator flashes 3 times at 1-second intervals for approx. 5
seconds, then the programming operation was not successful. All the memory locations in
the actuator or radio transmitter are occupied.
i
Press the
PROG
button once again for longer than 4 seconds to terminate the
programming mode earlier.
Disconnecting connection to an actuator
o
Carry out the same steps as when connecting (see the chapter Connecting to radio
actuator).
The status LED of the actuator flashes quickly for 5 seconds. The actuator is disconnected
from the radio transmitter. The actuator and radio transmitter exit the programming mode
automatically.
Reset button
All connections of the button (2) to the actuators are disconnected and parameters are reset to
default setting.
i
The connections in the actuators are preserved and must be deleted separately.
o
Press the
Prog
button for longer than 20 seconds.
The status LED (1) flashes red after 4 seconds. The status LED flashes faster after
20 seconds.
o
Release
Prog
button and press button (2) briefly once again within 10 seconds.
The status LED flashes more slowly for approx. 5 seconds.
The button (2) is reset. The setting as channel button or scene button is retained.
Resetting the hand-held transmitter to the default setting
All connections to actuators are disconnected and parameters are reset to default setting.
i
The connections in the actuators are preserved and must be deleted separately.
o
Press the
Prog
button for longer than 20 seconds.
The status LED (1) flashes red after 4 seconds. The status LED flashes faster after
20 seconds.
o
Release
Prog
button and press the
Prog
button briefly once again within 10 seconds.
The status LED flashes more slowly for approx. 5 seconds.
The hand-held transmitter is reset to default setting. Button (2) is set as channel button.
6 Appendix
Remove empty batteries immediately and dispose of in an environmentally friendly
manner. Do not throw batteries into household waste. Consult your local authorities
about environmentally friendly disposal. According to statutory provisions, the end
consumer is obligated to return used batteries.
The icon confirms the conformity of the product to the relevant guidelines.
4/6
82582503
J:0082582503
13.03.2014
eNet