Radio converter in SCHUKO housing

eNet

Radio converter in SCHUKO housing

Art. No. : FM GATE 1 ZSNA

Operating instructions

1 Safety instructions

Electrical equipment may only be installed and fitted by electrically skilled persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Adapter plugs may not be connected in series and must be easily accessible.

The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: Gateway

(1) SCHUKO socket with increased contact protection
(2) Red status LED, covered
(3) Button 

Prog

3 Function

System information

This device is a part of the eNet system and the Radio Management system.
The range of a radio system depends on various external circumstances. The range can be
optimised by the choice of installation location.
This device complies with the requirements of the R&TTE Directive 1999/5/EC. Declaration of
Conformity and further information on the eNet and Radio Management system can be found on
our website.
The device may be operated in all EU and EFTA countries.

Intended use

-

Control of eNet actuators by Radio Management transmitters

1/8

82582113
J:0082582113

13.03.2014

Summary of Contents for eNet FM GATE 1 ZSNA

Page 1: ...re an integral part of the product and must remain with the end customer 2 Device components Figure 1 Gateway 1 SCHUKO socket with increased contact protection 2 Red status LED covered 3 Button Prog 3...

Page 2: ...ion This device serves an interface between the Radio Management 433 MHz and eNet 868 MHz systems It allows operation of the actuators in the other system figure 2 i Status feedback is only provided b...

Page 3: ...Press the Prog button 3 of the gateway for approx 4 seconds The status LED 2 of the gateway flashes slowly The device is in programming mode for approx 1 minute o Switch the eNet transmitter to progr...

Page 4: ...r the scene button for longer than three seconds The connection to the actuator is disconnected The LED of the actuator flashes quickly o Exit the programming mode of the Radio Management actuators se...

Page 5: ...tors which are to react to the channel or scene button to programming mode as well see actuator instructions i Up to 10 eNet actuators can be connected at the same time o Press the channel button on t...

Page 6: ...ctions in the gateway between transmitters and actuators are disconnected Recommissioning must take place i Before resetting to the factory setting disconnect connected Radio Management actuators see...

Page 7: ...nction Manual commissioning On Off Basic setting On With this device the parameter has no function Sum status transmission repetitions On Off Transmit 2x 11x Off Transmit 4x without connection Basic s...

Page 8: ...e 1 58579 Schalksm hle Telefon 49 23 55 8 06 0 Telefax 49 23 55 8 06 2 04 kundencenter jung de www jung de Service Center Kupferstr 17 19 44532 L nen Germany 8 8 82582113 J 0082582113 13 03 2014 eNet...

Reviews: