Summary of Contents for 1208REG

Page 1: ...for rail mounting Art no 1208REG Pulse insert Art no 1708IE 15 08 2022 82599523 J0082599523 ALBRECHT JUNG GMBH CO KG Volmestraße 1 58579 Schalksmühle GERMANY Telefon 49 2355 806 0 Telefax 49 2355 806 204 kundencenter jung de www jung de ...

Page 2: ...se 3 3 Operation 4 4 Information for electrically skilled persons 5 4 1 Mounting and electrical connection 5 5 Technical data 7 6 Troubleshooting 9 7 Accessories 9 8 Warranty 9 2 10 82599523 15 08 2022 J0082599523 Power unit for rail mounting Pulse insert ...

Page 3: ... end cus tomer 2 Intended use Intended use of automatic RMD Manual or automatic switching of light in stairways Installation in sub distribution units on DIN rail according to DIN EN 60715 Switch on using pulse insert or push button The automatic RMD can also be used with pulse inserts from the light man agement Intended use of pulse insert Manual or automatic switch on of an automatic RMD Mountin...

Page 4: ...motion detectors being restarted During this time the motion detector cannot be operated via app Setting the automatic RMD Image 1 Automatic RMD Automatic function without switch off warning The lighting is switched off after the run on time elapses Automatic function with switch off warning After the run on time elapses the lighting is not switched off immediately but rather only after flashing t...

Page 5: ...x 30 seconds 4 Information for electrically skilled persons DANGER Mortal danger of electric shock Disconnect the device Cover up live parts 4 1 Mounting and electrical connection The automatic RMD can be used for a 3 conductor circuit Figure 2 or a 4 conductor circuit Figure 3 The 4 conductor circuit has the advantage that an additional lumin aire can be switched separately Image 2 Connection dia...

Page 6: ... heat sources e g RMD dimmers in the immediate vicinity of the auto matic RMD Ensure sufficient heat dissipation On control input A1 of the automatic RMD the aggregate current load must not exceed 40 mA To determine the current load add together the current con sumption of all connected pulse inserts and lighting elements of the push but tons If only pulse inserts with LB management motion detecto...

Page 7: ...insert 5 and push button 6 according to connection diagram Figure 2 or Figure 3 Fit pulse insert or push button in an appliance box pulse insert terminals must be at the bottom Install the cover frame and the cover If multiple circuit breakers supply dangerous voltages to the device or load couple the circuit breakers or label them with a warning so that disconnection from the supply voltage is en...

Page 8: ...amps uncompensated 1200 VA Fluorescent lamps parallel compensated 920 VA Fluorescent lamps duo circuit 2300 VA 140 μF Electronic transformers 1500 W Inductive transformers 1000 VA Electronic ballast Type dependent Installation width 18 mm 1 HP Total line length Power cable max 100 m Control cable max 100 m Pulse insert art no 1708IE Rated voltage AC 230 V Mains frequency 50 Hz Power consumption de...

Page 9: ...ctions for the cover Replacing defective devices in systems with light management devices Automatic RMD is defective The automatic RMD can be replaced one to one Light management pulse insert or cover is defective LB management covers and system inserts 1708IE can only be used in combination in existing installations Observe current consumption 7 Accessories LB Management push button 1 gang Art no...

Page 10: ...www jung de Power unit for rail mounting Pulse insert 10 10 82599523 15 08 2022 J0082599523 ...